Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[1839]
Temp. Input X48/10
[1840]
Analog Input X49/1
[1841]
Analog Input X49/3
[1842]
Analog Input X49/5
[1843]
Analog Out X49/7
[1844]
Analog Out X49/9
[1845]
Analog Out X49/11
[1846]
X49 Digital Output [bin]
[1847]
Last warning
[1848]
Last warning count
[1860]
Digital Input 2
[1870]
Mains Voltage
[1871]
Mains Frequency
[1872]
Mains Imbalance
[1873]
Worst Inrush
[1874]
Inrush Mode
[1875]
Rectifier DC Volt.
[1876]
Mains Voltage2
[1877]
Mains Frequency2
[1878]
Mains Imbalance2
[1879]
Rectifier DC Volt.2
[1890]
Process PID Error
© 2024.09
Description
This parameter shows the last warning.
This parameter shows how many times the last warning has been
active.
View the mains voltage measurement.
View the mains frequency measurement.
View the maximum measured imbalance for the 3 mains line-to-
line measurements.
Identifies which active inrush is producing the data shown
in parameter 18-70 Mains Voltage, parameter 18-71 Mains
Frequency, parameter 18-72 Mains Imbalance, and parameter
18-75 Rectifier DC Volt. 1 = inrush 1, 2 = inrush 2, and so on.
The reported mode of each inrush board.
Values: 0 = unknown, 1 = inrush, 2 = running.
Indexes: 0 = inrush 1, 1 = inrush 2, and so on.
View the DC voltage measurement from the rectifier module.
View the mains voltage measurement.
Indexes: 0 = inrush1 average, 1 = inrush2 average, 4 = inrush1 L1,
5 = inrush2 L1, 8 = inrush1 L2, and so on.
View the mains frequency measurement.
Indexes: 0 = inrush1 average, 1 = inrush2 average, 4 = inrush1 L1,
5 = inrush2 L1, 8 = inrush1 L2, and so on.
View the maximum measured imbalance for the 3 mains line-to-
line measurements.
Indexes: 0 = inrush1 average, 1 = inrush2 average, 4 = inrush1 L1,
5 = inrush2 L1, 8 = inrush1 L2, and so on.
View the DC voltage measurement from the rectifier module.
Indexes: 0 = inrush1 average, 1 = inrush2 average, 4 = inrush1 L1,
5 = inrush2 L1, 8 = inrush1 L2, and so on.
Shows the error value in the process PID controller.
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
59