Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[0]*
None
[1]
Standby encoder to T32/33
[2]
Standby encoder to T27/29
17-1* Inc. Enc. Interface
6.18.2
Do not use incremental encoders with PM motors. In a closed-loop control, consider absolute encoders or resolvers.
These parameters cannot be adjusted while the motor is running.
This parameter group contains parameters for configuring the incremental interface of the VLT® Encoder Input MCB 102. Both the
incremental and absolute interfaces are active at the same time.
17-10 Signal Type
Default value:
[1] RS422 (5V TTL)
Setup:
All setups
Data type:
Uint8
Select this parameter if 1 or 2 encoders are connected to MCB 102.
Option
Name
[0]
None
[1]*
RS422 (5V TTL)
[2]
Sinosoidal 1Vpp
17-11 Resolution (PPR)
Default value:
1024
Setup:
All setups
Data type:
Uint16
Enter the number of pulses or periods per revolution (the incremental track).
17-2* Abs. Enc. Interface
6.18.3
This parameter group contains parameters for configuring the absolute interface of the VLT® Encoder Input MCB 102. Both the
incremental and absolute interfaces are active at the same time.
17-20 Protocol Selection
Default value:
[0] None
© 2024.09
Description
No standby encoder.
Standby encoder connected to terminals 32 and 33.
Standby encoder connected to terminals 27 and 29.
NOTICE
NOTICE
Parameter type:
Conversion index:
Change during operation:
Description
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Parameter Descriptions
Option
–
False
Range, 10 - 16384
0
False
Option
AU275636650261en-003201 / 130R0334 |
577