Programming Guide | VLT® AutomationDrive FC 301/FC 302
32-14 Enc.2 Node ID
Default value:
127
Setup:
2 setups
Data type:
Uint8
Enter the node ID for the feedback CAN encoder.
32-15 Enc.2 CAN Guard
Default value:
[0] Off
Setup:
2 setups
Data type:
Uint8
Select if the feedback CAN encoder guardians should be off or on.
Option
Name
[0]*
Off
[1]
On
32-3* Encoder 1
6.28
32-30 Incremental Signal Type
Default value:
[1] RS422 (5V TTL)
Setup:
2 setups
Data type:
Uint8
Option
Name
[0]
None
[1]*
RS422 (5V TTL)
[3]
CAN encoder
32-31 Incremental Resolution
Default value:
1024
Setup:
2 setups
Data type:
Uint32
Set the resolution of the incremental encoder connected to terminal X56. The maximum frequency must not exceed 410 kHz.
32-32 Absolute Protocol
Default value:
[0] None
© 2024.09
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
Parameter type:
Conversion index:
Change during operation:
Description
Parameter type:
Conversion index:
Change during operation:
Parameter type:
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
Range, 1 - 127
0
True
Option
–
True
Option
–
True
Range, 1 - 1073741823
0
True
Option
661