Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[226]
Touch on target
[227]
Touch activated
[228]
Comparator 6
[229]
Comparator 7
[230]
Comparator 8
[231]
Comparator 9
[232]
Logic rule 6
[233]
Logic rule 7
[234]
Logic rule 8
[235]
Logic rule 9
[236]
SL time-out 8
[237]
SL time-out 9
[238]
RS flipflop 8
[239]
RS flipflop 9
[240]
SL digital output A
[241]
SL digital output B
[242]
SL digital output C
[243]
SL digital output D
[244]
SL digital output E
[245]
SL digital output F

13-2* Timers

6.14.5
Use the result (true or false) from timers directly to define an event (see parameter 13-51 Controller Event), or as boolean input in a logic
rule (see parameter 13-40 Logic Rule Boolean 1, parameter 13-42 Logic Rule Boolean 2, or parameter 13-44 Logic Rule Boolean 3). A timer
is only false when started by an action, for example, [29] Start timer 1, until the timer value entered in this parameter has elapsed. Then
it becomes true again. All parameters in this parameter group are array parameters with indexes 0–9. Select index 0 to program timer 0,
select index 1 to program timer 1, and so on.
444
| © 2024.09
Description
  NOTICE
This option is only available with software version 48.2X
and newer.
Target position is reached in touch probe position mode.
  NOTICE
This option is only available with software version 48.2X
and newer.
Touch probe positioning active. The drive monitors the touch
probe sensor input.
Parameter Descriptions
AU275636650261en-003201 / 130R0334