Digital/Bus - Danfoss VLT AutomationDrive FC 301 Programming Manual

Software versions 9.5x and 48.96
Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[0]*
Off
[1]
Transaction started
[2]
Commit transaction
[3]
Transaction timeout
[4]
Err. non-existing par.
[5]
Err. par. out of range
[6]
Transaction failed
[7]
SO config check
[8]
SO config check done
8-47 BTM Timeout
Default value:
60 s
Setup:
1 setup
Data type:
Uint16
Select the BTM timeout after a BTM transaction has been started. Timeout is between each acyclic write of parameters.
8-48 BTM Maximum Errors
Default value:
21
Setup:
1 setup
Data type:
Uint8
Select the maximum allowed number of bulk transfer mode errors before aborting. If it is set to maximum, there is no abort.
8-49 BTM Error Log
Defaul value:
Size related
Setup:
1 setup
Data type:
Uint32
List of parameters that failed during bulk transfer mode. The value after the decimal break is the fault code (255 stands for no error).
6.10.6

8-5* Digital/Bus

This parameter group contains parameters for configuring the control word merging.
8-50 Coasting Select
Default value:
[3] Logic OR
Setup:
All setups
Data type:
Uint8
© 2024.09
Description
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
Range, 1 - 360 s
0
False
Range, 0 - 21
0
True
Range, 0.000 - 9999.255, Array
[22]
-3
True
Option
True
345