Programming Guide | VLT® AutomationDrive FC 301/FC 302
47-13 Previous Mean
Default value:
0%
Setup:
All setups
Data type:
Uint16
This parameter shows the average of stator winding readings for the previous baseline.
47-14 Previous Min
Default value:
0%
Setup:
All setups
Data type:
Uint16
The parameter shows the minimum value of motor stator windings for previous baseline.
47-15 Previous Counter
Default value:
0
Setup:
All setups
Data type:
Uint16
The parameter shows the previous minutes to capture monitoring values for speed points.
47-1* Stator Res. Active
6.42.4
47-16 Actual Max
Default value:
0%
Setup:
All setups
Data type:
Uint16
This parameter shows the active stator resistance.
47-17 Actual Mean + 3 Std. Dev.
Default value:
0%
Setup:
All setups
Data type:
Uint16
This parameter shows the mean and 3 standard deviations of stator resistance readings for the active baseline.
47-18 Actual Mean
Default value:
0%
Setup:
All setups
Data type:
Uint16
Shows the mean of stator resistance recordings for active load in the active baseline.
788
| © 2024.09
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter Descriptions
Range, 0 - 100%, Array [20]
-2
True
Range, 0 - 100%, Array [20]
-2
True
Range, 0 - 0, Array [20]
0
False
Range, 0 - 100%, Array [20]
-2
False
Range, 0 - 100%, Array [20]
-2
False
Range, 0 - 100%, Array [20]
-2
False