When [5] 1st start check motor or [6] Every st. check motor is selected in parameter 1-47 Torque Characteristics, the last estimated Ld is
shown.
44-29 Estimated Back EMF at 1000 RPM
Default value:
0 V
Setup:
All setups
Data type:
Uint32
When [5] 1st start check motor or [6] Every st. check motor is selected in parameter 1-47 Torque Characteristics, the last estimated Back
EMF at 1000 RPM is shown.
Parameter Group 45-** Condition Based Monitoring
6.40
6.40.1
45-0* Cockpit: Monitor
Use this parameter group to enable condition-based monitoring, define units, baseline computation, input sources, view baseline status,
and progress.
45-00 Function
Default value:
[0] Off
Setup:
2 setups
Data type:
Uint8
Set type of notification level and to enable monitoring of the drive.
Option
Name
[0]*
Off
[1]
Warning
[2]
Alarm & warning
Table 56: Parameter Index
Parameter ID
45-00.0
45-00.1
45-00.2
45-00.3
45-01 Status
Default value:
[0] Off
Setup:
2 setups
Data type:
Uint8
© 2024.09
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
Notification is disabled.
Warning notifications are triggered.
Both alarm and warning notifications are triggered.
Description
Select the required option to enable stator winding monitoring.
Select the required option to enable load envelope
Select the required option to enable sensor 1 vibration.
Select the required option to enable sensor 2 vibration.
Parameter type:
Conversion index:
Change during operation:
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
Range, 0 - 65000 V
-1
True
Option
–
False
Option
–
False
759