Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[141]
ft/min
[145]
ft
[150]
lb ft
[160]
°F
[170]
psi
[171]
lb/in
[172]
in WG
[173]
ft WG
[180]
HP
3-02 Minimum Reference
Default value:
Size related
Setup:
All setups
Data type:
Int32
Enter the minimum reference. The minimum reference is the lowest value obtainable by summing all references. Minimum reference is
active only when parameter 3-00 Reference Range is set to [0] Min.- Max. The minimum reference unit matches:
The configuration of parameter 1-00 Configuration Mode: For [1] Speed closed loop, RPM; for [2] Torque, Nm.
l
The unit selected in parameter 3-01 Reference/ Feedback Unit.
l
If option [10] Synchronization is selected in parameter 1-00 Configuration Mode, this parameter defines the maximum speed deviation
when performing the position offset defined in parameter 3-26 Master Offset. Also see parameter 3-28 Master Offset Speed Ref.
3-03 Maximum Reference
Default value:
Size related
Setup:
All setups
Data type:
Int32
Enter the maximum reference. The maximum reference is the highest value obtainable by summing all references. The maximum
reference unit matches:
The configuration selected in parameter 1-00 Configuration Mode: For [1] Speed closed loop, RPM; for [2] Torque, Nm.
l
The unit selected in parameter 3-00 Reference Range.
l
If [9] Positioning is selected in parameter 1-00 Configuration Mode, this parameter defines the default speed for positioning.
3-05 On Reference Window
Default value:
Size related
146
| © 2024.09
3
Description
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Parameter Descriptions
Range, -999999.999 -
999999.999 Reference-
FeedbackUnit
-3
True
Range, 0.000 - 999999.999
Reference FeedbackUnit
-3
True
Range, 0 - 999999.999
ReferenceFeedbackUnit
AU275636650261en-003201 / 130R0334