Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[225]
Position limit
[226]
Touch on target
[227]
Touch activated
[249]
Therm. sensor temp.
13-11 Comparator Operator
Default value:
–
Setup:
2 setups
Data type:
Uint8
Select the operator to be used in the comparison. This is an array parameter containing comparator operators 0–5.
Option
Name
[0]
<
≂ (equal)
[1]
© 2024.09
Description
NOTICE
This option is only available with software version 48.2X
and newer.
The position is outside the limits set in parameter 3-06 Minimum
Position and parameter 3-07 Maximum Position.
NOTICE
This option is only available with software version 48.2X
and newer.
Target position is reached in touch probe position mode.
NOTICE
This option is only available with software version 48.2X
and newer.
Touch probe positioning is active. The drive monitors the touch
probe sensor input.
Parameter type:
Conversion index:
Change during operation:
Description
NOTICE
If [20] Alarm number or [21] Warning number is selected
in parameter 3-10 Comparator Operand, [0] < cannot be
selected in this parameter.
The result of the evaluation is true when the variable selected in
parameter 13-10 Comparator Operand is smaller than the fixed
value in parameter 13-12 Comparator Value. The result is false if
the variable selected in parameter 13-10 Comparator Operand
is greater than the fixed value in parameter 13-12 Comparator
Value.
The result of the evaluation is true when the variable selected in
parameter 13-10 Comparator Operand is approximately equal to
the fixed value in parameter 13-12 Comparator Value.
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
Option, Array [10]
–
True
433
Need help?
Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?