Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[76]
Start timer 9
[120]
Start homing
[121]
Stop homing
[122]
Enable reference
[123]
Disable reference
[124]
Relative position
[125]
Absolute position
© 2024.09
Description
Starts timer 9, see parameter 13-20 SL Controller Timer for
further description.
  NOTICE
This option is available only with software version 48.20
and newer.
Activates the homing mode and starts the homing function
selected in parameter 17-80 Homing Function. Must remain
active until the homing is completed otherwise the homing is
aborted.
  NOTICE
This option is available only with software version 48.20
and newer.
Deactivates the homing mode, an active homing function is
aborted if the homing is not completed.
  NOTICE
This option is available only with software version 48.20
and newer.
Sets the enable reference mode.
  NOTICE
This option is available only with software version 48.20
and newer.
Disables the enable reference mode.
  NOTICE
This option is available only with software version 48.20
and newer.
Selects the relative position mode instead of the absolute
position mode.
  NOTICE
This option is available only with software version 48.20
and newer.
Selects the absolute position mode instead of the relative
position mode.
AU275636650261en-003201 / 130R0334 |