Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[0]
24 h
[1]
12 h
0-73 Time Zone Offset
Default value:
0 min
Setup:
2 setups
Data type:
Int16
Enter the time zone offset relative to UTC. This parameter is required for the automatic daylight saving time adjustment.
0-74 DST/Summertime
Default value:
[0] Off
Setup:
1 setup
Data type:
Uint8
Select how to handle daylight saving time/summer time. For manual setting of DST/summer time, enter the start date and end date in
parameter 0-76 DST/Summertime Start and parameter 0-77 DST/Summertime End.
Option
Name
[0]*
Off
[2]
Manual
0-75 Last Power Off Time
Default value:
Size related
Setup:
All setups
Data type:
TimeOfDay
This parameter stores the last 5 drive power-off timestamps. Index [0] is the latest power-off time, and index [4] is the oldest.
0-76 DST/Summertime Start
Default value:
Size related
Setup:
1 setup
Data type:
TimeOfDay
Sets the date and time when DST/summer time starts. The date is programmed in the format selected in parameter 0-71 Date Format.
0-77 DST/Summertime End
Default value:
Size related
Setup:
1 setup
74
| © 2024.09
Description
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Data type:
Parameter Descriptions
Range, -780 - 780 min
70
False
Option
–
True
Range, 0 - 0, Array [5]
0
True
Range, 0 - 0
0
True
Range, 0 - 0
TimeOfDay
AU275636650261en-003201 / 130R0334
Need help?
Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?
Questions and answers