Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[0]*
Actual position
[1]
Commanded position
[2]
Master position
[3]
Vir. master position
24-61 Axis Direction B
Default value:
[2] Both directions
Setup:
All setups
Data type:
Uint8
Select for which speed directions digital CAM switch B is to be active.
Option
Name
[0]
Clockwise
[1]
Counter clockwise
[2]*
Both directions
24-62 First Position B
Default value:
0 AbsolutePositionUnit
Setup:
All setups
Data type:
Int32
Select the 1st position defining the digital CAM switch B.
24-63 Last Position B
Default value:
0 AbsolutePositionUnit
Setup:
All setups
Data type:
Int32
Select the last position defining digital CAM switch B.
642
| © 2024.09
Description
Parameter type:
Conversion index:
Change during operation:
Description
Digital CAM switch B is only set when approaching the CAM
switch position in clockwise direction.
Digital CAM switch B is only set when approaching the CAM
switch position in counterclockwise direction.
Digital CAM switch B is set when approaching the CAM switch
position in both direction.
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter Descriptions
Option, Array [2]
–
True
Range, -2147483648
- 2147483647
AbsolutePositionUnit, Array [2]
0
True
Range, -2147483648
- 2147483647
AbsolutePositionUnit, Array
[ 2]
0
True
AU275636650261en-003201 / 130R0334