Programming Guide | VLT® AutomationDrive FC 301/FC 302
24-64 On Compensation B
Default value:
0 ms
Setup:
All setups
Data type:
Uint16
Enables compensation for delay in the component switched by the digital CAM switch output. The drive calculates the distance it will
move within the On compensation time based on the actual speed. The output will be switched on at this distance before the set first or
last position.
24-65 Off Compensation B
Default value:
0 ms
Setup:
All setups
Data type:
Uint16
Enables compensation for delay in the component switched by the digital CAM switch output. The drive calculates the distance is will
move within the off compensation time based on the actual speed.The output will then be switched off at this distance before the set first
or last position.
24-7* Anti-sway Ramp
6.23.5
24-70 Min Ref. Change
Default value:
50 RPM
Setup:
All setups
Data type:
Uint16
This parameter is only available in software version 48.96 or newer.
Set the minimum reference change for using the anti-sway ramp. A linear ramp is used for speed references changes below the set value.
24-71 Rope Length
Default value:
5.00 m
Setup:
All setups
Data type:
Uint16
This parameter is only available in software version 48.96 or newer.
Set the length of the rope carrying the load. This is needed to calculate the anti-sway ramp profile. Alternatively, the period of swing can
be set in parameter 24-72 Period of Swing.
24-72 Period of Swing
Default value:
0.00 s
© 2024.09
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
NOTICE
Parameter type:
Conversion index:
Change during operation:
NOTICE
Parameter type:
Parameter Descriptions
Range, 0 - 10000 ms
-3
True
Range, 0 - 10000 ms
-3
True
Range, 0 - 32000 RPM, Array [4]
67
True
Range, 0.01 - 650.00 m, Array
[4]
-2
True
Range, 0.00 - 650.00 s, Array [4]
AU275636650261en-003201 / 130R0334 |
643