Programming Guide | VLT® AutomationDrive FC 301/FC 302
Data type:
Uint16
Use this parameter for reading out the actual DeviceNet product code.
10-39 Devicenet F Parameters
Default value:
0
Setup:
All setups
Data type:
Uint32
Use this parameter to configure the drive via DeviceNet and build the EDS file.
6.12.5
10-5* CANopen
10-50 Process Data Config Write
Default value:
Size related
Setup:
All setups
Data type:
Uint16
Only elements [2] and [3] of this array can be selected. [0] and [1] are fixed.
Option
Name
[0]
None
[109]
Mode of operation
[302]
Minimum reference
[303]
Maximum reference
[311]
Jog speed [Hz]
[312]
Catch up/slow down value
[319]
Jog speed [RPM]
[321]
Touch target
[322]
Master scale numerator
[323]
Master scale denominator
[326]
Master Offset
[328]
Master offset speed ref
[330]
Min. speed ramp time
[341]
Ramp 1 ramp up time
[342]
Ramp 1 ramp down time
[351]
Ramp 2 ramp up time
[352]
Ramp 2 ramp down time
[361]
Ramp 3 ramp up time
© 2024.09
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
True
Range, 0 - 0, Array [1000]
0
True
Option, Array [81]
–
True
387