Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[26]
Home sensor
[27]
Touch sensor
[28]
Position vir. master
[29]
Set master home
326
| © 2024.09
Description
NOTICE
This option is only available with software version 48.XX.
NOTICE
Accuracy of the home position depends on the delay in
transferring the signals.
The home sensor is connected via fieldbus master.
NOTICE
This option is only available with software version 48.XX.
NOTICE
Accuracy of touch probe positioning depends on the
delay in transferring the signals.
The touch sensor is connected via fieldbus master.
NOTICE
This option is only available with software version 48.XX.
Activates position-controlled virtual master when [9] Positioning
or [10] Synchronization is selected in parameter 1-00
Configuration Mode. When the option is selected, the following
occurs:
• Target position is set by Fieldbus Pos Ref or preset target is as
defined in parameter 3-20 Preset Target.
• Speed is set relative to parameter 3-27 Virtual Master Max Ref
by the source selected in parameter 3-15 Reference Resource 1
or fieldbus REF1.
• Acceleration and deceleration are set as defined in parameter
group 3-6* Ramp 3.
NOTICE
This option is only available with software version 48.XX.
Sets the actual master position as defined in parameter 17-88
Master Home Position.
Parameter Descriptions
AU275636650261en-003201 / 130R0334