Danfoss VLT AutomationDrive FC 301 Programming Manual page 326

Software versions 9.5x and 48.96
Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[26]
Home sensor
[27]
Touch sensor
[28]
Position vir. master
[29]
Set master home
326
| © 2024.09
Description
  NOTICE
This option is only available with software version 48.XX.
  NOTICE
Accuracy of the home position depends on the delay in
transferring the signals.
The home sensor is connected via fieldbus master.
  NOTICE
This option is only available with software version 48.XX.
  NOTICE
Accuracy of touch probe positioning depends on the
delay in transferring the signals.
The touch sensor is connected via fieldbus master.
  NOTICE
This option is only available with software version 48.XX.
Activates position-controlled virtual master when [9] Positioning
or [10] Synchronization is selected in parameter 1-00
Configuration Mode. When the option is selected, the following
occurs:
• Target position is set by Fieldbus Pos Ref or preset target is as
defined in parameter 3-20 Preset Target.
• Speed is set relative to parameter 3-27 Virtual Master Max Ref
by the source selected in parameter 3-15 Reference Resource 1
or fieldbus REF1.
• Acceleration and deceleration are set as defined in parameter
group 3-6* Ramp 3.
  NOTICE
This option is only available with software version 48.XX.
Sets the actual master position as defined in parameter 17-88
Master Home Position.
Parameter Descriptions
AU275636650261en-003201 / 130R0334

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AutomationDrive FC 301 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents

Save PDF