Programming Guide | VLT® AutomationDrive FC 301/FC 302
Time period where the option is allowed to be below 120 RPM when SLS is active before STO is activated.
42-19 Zero Speed Limit
Default value:
120 RPM
Setup:
1 setup
Data type:
Uint16
Enter the zero-speed limit. If SLS is active, and if the motor speed is lower than this limit, parameter 42-18 Zero Speed Timer is activated.
6.37.4
42-2* Safe Input
42-20 Safe Function
Default value:
Setup:
All setups
Data type:
Uint8
Enable any of the safety options or disable safety option for the digital safe inputs.
Option
Name
[0]
STO
[1]
SS1-a
[2]
SS1-b
[3]
SLS-a
[4]
SLS-b
[5]
Disable
[8]
SO mon
42-21 Type
Default value:
[0] NCNC
Setup:
All setups
Data type:
Uint8
Option
Name
[0]*
NCNC
[1]
Antivalent
[2]
NC
[3]
NO
© 2024.09
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Description
Parameter type:
Conversion index:
Change during operation:
Description
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
Range, 1 - 600 RPM
0
False
Option
False
Option
False
743