47-19 Actual Min
Default value:
0%
Setup:
All setups
Data type:
Uint16
Shows the minimum of all stator resistance recordings for active load in the active baseline.
47-20 Previous Max
Default value:
0%
Setup:
All setups
Data type:
Uint16
This parameter shows the maximum stator resistance readings for the previous baseline.
47-21 Previous Mean + 3 Std. Dev.
Default value:
0%
Setup:
All setups
Data type:
Uint16
This parameter shows the mean and 3 standard deviations of stator resistance readings for the previous baseline.
47-22 Previous Mean
Default value:
0%
Setup:
All setups
Data type:
Uint16
This parameter shows the average of stator resistance readings for the previous baseline.
47-23 Previous Min
Default value:
0%
Setup:
All setups
Data type:
Uint16
The parameter shows the minimum value of motor stator resistance for previous baseline.
47-2* Stator Res. Load
6.42.5
47-24 Actual Max
Default value:
0%
Setup:
All setups
Data type:
Uint16
© 2024.09
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
Range, 0 - 100%, Array [20]
-2
False
Range, 0 - 100%, Array [20]
-2
False
Range, 0 - 100%, Array [20]
-2
False
Range, 0 - 100%, Array [20]
-2
False
Range, 0 - 100%, Array [10]
-2
False
Range, 0 - 655.35%, Array [40]
-2
False