Programming Guide | VLT® AutomationDrive FC 301/FC 302
Select the trigger for the coasting function.
Option
Name
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3]*
Logic OR
8-51 Quick Stop Select
Default value:
[3] Logic OR
Setup:
All setups
Data type:
Uint8
Select the trigger for the quick stop function.
Option
Name
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3]*
Logic OR
8-52 DC Brake Select
Default value:
–
Setup:
All seutps
Data type:
Uint8
Select control of the DC brake via the terminals (digital input) and/or via the fieldbus.
When parameter 1-10 Motor Construction is set to [1] PM non-salient SPM, only selection [0] Digital input is available.
346
| © 2024.09
Description
A digital input triggers the coasting function.
A serial communication port or the fieldbus triggers the coasting
function.
The fieldbus/serial communication port and a digital input
trigger the coasting function.
The fieldbus/serial communication port or a digital input triggers
the coasting function.
Parameter type:
Conversion index:
Change during operation:
Description
A digital input triggers the quick stop function.
A serial communication port or the fieldbus triggers the quick
stop function.
The fieldbus/serial communication port and a digital input
trigger the quick stop function.
The fieldbus/serial communication port or a digital input triggers
the quick stop function.
Parameter type:
Conversion index:
Change during operation:
NOTICE
Parameter Descriptions
Option
–
True
Option
–
True