Programming Guide | VLT® AutomationDrive FC 301/FC 302
This parameter is only available with software version 48.XX.
Set up to 8 target positions. Select from the 8 preset positions using digital inputs or the fieldbus control word.
3-21 Touch Target
Default value:
0 AbsolutePositionUnit
Setup:
All setups
Data type:
Int32
This parameter is only available with software version 48.XX.
2147483647 = Latch Only. With Latch Only actual position of touch sensor is latched and updated in parameter 18-25 Latched Actual Pos
but no positioning is executed. Enter the target position in touch probe positioning mode. This parameter defines the distance from the
detection event of the touch probe sensor to the final target position in position units.
3-22 Master Scale Numerator
Default value:
1
Setup:
All setups
Data type:
Int32
This parameter is only available with software version 48.XX.
Parameter 3-22 Master Scale Numerator and parameter 3-23 Master Scale Denominator define the gear ratio between the master and
the follower in synchronization mode.
3-23 Master Scale Denominator
Default value:
1
Setup:
All setups
Data type:
Int32
This parameter is only available with software version 48.XX.
Refer to Parameter 3-22 Master Scale Numerator.
© 2024.09
  NOTICE
Parameter type:
Conversion index:
Change during operation:
  NOTICE
Parameter type:
Conversion index:
Change during operation:
  NOTICE
Parameter type:
Conversion index:
Change during operation:
  NOTICE
Parameter Descriptions
Range, -2147483648
- 2147483647
AbsolutePositionUnit
0
True
Range, -2147483648 -
2147483647
0
True
Range, -2147483648 -
2147483647
0
True