Programming Guide | VLT® AutomationDrive FC 301/FC 302
Option
Name
[126]
Activate touch
[127]
Deactivate touch
[128]
Target inverse
[129]
Target
[130]
Act. speed mode
[131]
Deact. speed mode
13-55 SL Controller 3 Event
Default value:
–
Setup:
2 setups
Data type:
Uint8
478
| © 2024.09
Description
NOTICE
This option is available only with software version 48.20
and newer.
Activates the touch probe positioning mode.
NOTICE
This option is available only with software version 48.20
and newer.
Deactivates the touch probe positioning mode.
NOTICE
This option is available only with software version 48.20
and newer.
Changes the sign of the active target position value.
NOTICE
This option is available only with software version 48.20
and newer.
The active target position is not changed.
NOTICE
This option is available only with software version 48.20
and newer.
Activates the speed mode when option [9] Positioning or option
[10] Synchronization is selected in parameter 1-00 Configuration
Mode.
NOTICE
This option is available only with software version 48.20
and newer.
Deactivates the speed mode and activates the option selected in
parameter 1-00 Configuration Mode.
Parameter type:
Conversion index:
Change during operation:
Parameter Descriptions
Option, Array [20]
–
True