Programming Guide | VLT® AutomationDrive FC 301/FC 302
Data type:
Uint16
Set the threshold value which defines a low alarm for load envelope monitoring. When the value of the monitored value exceeds the
threshold specified in the parameter for the duration of time specified in alarm time, a low alarm is triggered. The parameter contains 20
index values which can be used to manually configure Vibration 1 Alarm High Threshold for each individual speed point.
46-41 Warning S2 High
Default value:
0%
Setup:
All setups
Data type:
Uint16
Set the threshold value which defines a low alarm for load envelope monitoring. When the value of the monitored value exceeds the
threshold specified in the parameter for the duration of time specified in alarm time, a low alarm is triggered. The parameter contains 20
index values which can be used to manually configure Vibration 1 Warning S2 High Threshold for each individual speed point.
46-42 Warning S1 High
Default value:
0%
Setup:
All setups
Data type:
Uint16
Set the threshold value which defines a low alarm for load envelope monitoring. When the value of the monitored value exceeds the
threshold specified in the parameter for the duration of time specified in alarm time, a low alarm is triggered. The parameter contains 20
index values which can be used to manually configure Vibration 1 Warning S2 High Threshold for each individual speed point.
46-5* Sensor 2
6.41.7
Use the parameters in this group to enter, adjust, and display threshold values for Sensor 2 monitoring function.
46-50 Alarm High
Default value:
0%
Setup:
All setups
Data type:
Uint16
Set the threshold value which defines a low alarm for load envelope monitoring. When the value of the monitored value exceeds the
threshold specified in the parameter for the duration of time specified in alarm time, a low alarm is triggered. The parameter contains 20
index values which can be used to manually configure Vibration 2 Alarm High Threshold for each individual speed point.
46-51 Warning S2 High
Default value:
0%
Setup:
All setups
Data type:
Uint16
Set the threshold value which defines a low alarm for load envelope monitoring. When the value of the monitored value exceeds the
threshold specified in the parameter for the duration of time specified in alarm time, a low alarm is triggered. The parameter contains 20
index values which can be used to manually configure Vibration 2 Warning S2 High Threshold for each individual speed point.
© 2024.09
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
Parameter type:
Conversion index:
Change during operation:
AU275636650261en-003201 / 130R0334 |
Parameter Descriptions
True
Range, 0 - 100%, Array [20]
-2
True
Range, 0 - 100%, Array [20]
-2
True
Range, 0 - 100%, Array [20]
-2
True
Range, 0 - 100%, Array [20]
-2
True
783