When avoiding to set the Connector Conversion Box to the emergency stop state while Handy GOT
(b)
is removed
GT14 Handy
ES-1
ES-2
ES-3
The internal contact operates as follows.
• When the Connector Conversion Box is supplied with the power and the power switch is ON (POWER LED
turns on.) Since the internal contact opens and the insulation status occurs between ES  Bs, the status
between ES  As coordinates with those of the emergency stop switch and the external cable.
• When the Connector Conversion Box is not supplied with the power and the power switch is OFF (POWER
LED turns off.) Since the internal contact closes and the short-circuit status occurs between ES  Bs, the
status between ES  As closes regardless of the status of the emergency stop switch and the external cable.
(2) When using the connector conversion box (GT11H-CNB-37S or GT16H-CNB-37S)
(a) When setting the Connector conversion box to the emergency stop state while Handy GOT is removed
GT14 Handy
ES-1
ES-2
ES-3
Connector conversion box
Terminal
block 1)
20
ES1A
19
18
ES1B
17
Internal contact
16
ES2A
15
14
ES2B
13
12
ES3A
11
10
ES3B
9
Connector conversion box
Terminal
block 2)
14
ES-1
13
12
ES-2
11
1
ES-3
2
9. HANDLING OF POWER WIRING AND SWITCH
Used as control
signals of external
device power ON/OFF
Used as control
signals of external
device power ON/OFF
9.4 Switch Wiring
9
10
11
12
13
14
15
16
9 - 17