37.4 GOT Side Settings

37.4.1
Setting communication interface
(Communication settings)
Set the channel of the equipment connected to the GOT.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: JTEKT
• Controller Type: JTEKT TOYOPUC-PC
• I/F: Interface to be used
• Driver: JTEKT TOYOPUC-PC
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
37.4.2 Communication detail settings
OK
Click the
button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
18.1.2 I/F communication setting
37.4.2 Communication detail settings
Make the settings according to the usage environment.
Item
Transmission
Speed
3.
Data Bit
Stop Bit
4.
Parity
Retry
Click!
Timeout Time
Delay Time
Host Address
Format
POINT
POINT
POINT
(1) Format setting
PC2J, PC2JS, PC2JR, PC2JC, PC2J16P,
PC2J16PR
PC3JG, PC3JG-P, PC3JD, PC3JD-C,
PC3J, PC3JL
(2) Communication interface setting by Utility
(3) Precedence in communication settings
37. CONNECTION TO JTEKT PLC
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment. (Default: 19200bps)
Set this item when change the data length
used for communication with the
connected equipment. (Default: 8bit)
Specify the stop bit length for
communications. (Default: 1bit)
Specify whether or not to perform a parity
check, and how it is performed during
communication. (Default: Even)
Set the number of retries to be performed
when a communication error occurs.
(Default: 0time)
Set the time period for a communication
to time out. (Default: 3sec)
Set this item to adjust the transmission
timing of the communication request from
the GOT. (Default: 0)
Specify the host address (station No. of
the GOT to which the PLC is connected)
in the connected network. (Default: 00)
Select the communication format.
(Default: 1)
format 1: PC3J extended function incompliant
format 2: PC3J extended function compliant
The compatible format of PLC differs depending
on model.
Model
For details of PC3J extended function, refer to the
following manual.
JTEKT PLC user's manual
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
37.4 GOT Side Settings
32
33
Range
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
7bit/8bit
34
1bit/2bits
None
Even
Odd
0 to 5times
35
3 to 30sec
0 to 300ms
00 to 37
(Octal)
36
1/2
37
Compatible format
Format 1 only
Format 1 or Format 2
38
39
37 - 17