  • Page 1 GT10 User s Manual...
  • Page 3 SAFETY PRECAUTIONS (Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING"...
  • Page 4 [DESIGN PRECAUTIONS] WARNING Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is gone out. When the GOT backlight goes out, the display section dims, while the input of the touch switch(s) remains active. This may confuse an operator in thinking that the GOT is in "screensaver"...
  • Page 5 CAUTION Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration. When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range.
  • Page 6 [TEST OPERATION PRECAUTIONS] WARNING Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter), read through the manual carefully and make yourself familiar with the operation method.
  • Page 7 Not doing so can cause the unit to fail or malfunction. Replace battery with GT11-50BAT by Mitsubishi electric Co. only. Use of another battery may present a risk of fire or explosion. Dispose of used battery promptly.
  • Page 8 [TRANSPORTATION PRECAUTIONS] CAUTION When transporting lithium batteries, make sure to treat them based on the transport regulations. (Refer to Appendix 3 for details of the regulated units.) Before transporting the GOT, turn the GOT power on and check that the battery voltage status is normal on the Time setting &...
  • Page 9 REVISIONS The manual number is given on the bottom left of the back cover. Print Date Manual Number Ver. Revision Nov., 2006 JY997D24701 First edition Jun, 2007 JY997D24701 Partial correcting SAFETY PRECAUTIONS, ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL, HOW TO READ THIS MANUAL, Section 1.1, 2.2, 3.2, 3.3, Chapter 4, Section 6.2, 6.3, 7.1, 8.1, 8.2, Chapter 9, Section 11.1, Chapter 12, 13, Section 14.1, Chapter 15, Section 16.2, App - 1, App - 2, App - 4 Additions...
  • Page 10 Print Date Manual Number Ver. Revision Mar., 2009 JY997D24701 Partial correcting SAFETY PRECAUTIONS, ABBREVIATIONS AND GENERIC TERMS, HOW TO READ THIS MANUAL, Chapter 2, Section 3.1, 3.2, Section 4.2, Section 8.3, Section 9.1, Section 12.1, Section 18.4, App-1, App-2, App-4, Index Additions Section 8.8, Section 8.9...
  • Page 11 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 12 • Since the example indicated by this manual, technical bulletin, the catalog, etc. is reference, please use it after confirming the function and safety of equipment and system when employing. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples.
  • Page 13 CONTENTS SAFETY PRECAUTIONS ....................A-1 REVISIONS........................A-7 INTRODUCTION......................A-10 OUTLINE PRECAUTIONS....................A-10 CONTENTS ........................A-11 ABOUT MANUALS .......................A-17 ABBREVIATIONS AND GENERIC TERMS..............A-19 HOW TO READ THIS MANUAL ...................A-24 1. OVERVIEW............1-1 to 1-5 1.1 Features ........................1-4 1.2 Rough Pre-operation Procedure ................1-5 2. SYSTEM CONFIGURATION ......2-1 to 2-11 2.1 Overall Configuration ....................
  • Page 14 6. INSTALLATION..........6-1 to 6-11 6.1 Control Panel Inside Dimensions for Mounting GOT..........6-2 6.1.1 GT1020 ............................6-2 6.1.2 GT1030 ............................6-3 6.1.3 GT104[ ] ............................6-4 6.1.4 GT105[ ] ............................6-5 6.2 Panel Cutting Dimensions ..................6-6 6.2.1 Panel cutting dimensions ........................6-6 6.3 Mounting Position .......................6-7 6.3.1 Mounting position..........................6-7 6.4 Control Panel Temperature and Mounting Angle ............6-9 6.4.1 Control panel temperature and mounting angle................6-9...
  • Page 15 8.6 Stand........................8-26 8.6.1 Applicable stand..........................8-26 8.6.2 Installing procedure........................8-26 8.7 Protective cover for oil....................8-27 8.7.1 Applicable protective cover for oil ....................8-27 8.7.2 Installing procedure........................8-27 8.8 Serial Multi-Drop Connection Unit................8-29 8.8.1 Serial multi-drop connection unit....................8-29 8.8.2 Applicable serial multi-drop connection unit..................
  • Page 16 11.4 Keyword........................11-18 11.4.1 Keyword functions........................11-18 11.4.2 Keyword display operation......................11-18 11.4.3 Regist............................11-19 11.4.4 Delete............................11-22 11.4.5 Clear ............................11-23 11.4.6 Protect............................11-24 12. DISPLAY AND OPERATION SETTINGS (GOT SET UP)..........12-1 to 12-16 12.1 Display Settings......................12-2 12.1.1 Display setting functions ......................12-2 12.1.2 Display operation of display setting ....................12-3 12.1.3 Display setting operations......................12-4 12.2 Operation Settings....................12-8 12.2.1 Operation setting functions ......................12-8...
  • Page 17 15. GOT DEBUG ..........15-1 to 15-48 15.1 Debug........................15-1 15.2 Device Monitor ....................... 15-1 15.2.1 System configuration ........................15-1 15.2.2 Devices that can be monitored ....................15-2 15.2.3 Precautions ..........................15-2 15.2.4 Display operation of device monitor.................... 15-3 15.2.5 Information displayed on the device monitor screen and key functions........15-4 15.2.6 Basic operation of device monitor....................
  • Page 18 18.5 Backlight Shutoff Detection ..................18-6 18.5.1 Backlight shutoff detection and external alarm ................18-6 APPENDICES ..........App-1 to App-15 Appendix 1 External Dimensions ................App- 1 Appendix 2 Usage Condition of Utility Function ............. App- 12 Appendix 3 Transportation Precautions ..............App- 14 Appendix 4 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000 Series) ................
  • Page 19 ABOUT MANUALS The following manuals are also related to this product. In necessary, order them by quoting the details in the tables below. Related Manuals Manual Number Manual Name (Model Code) GT Designer2 Version2 Basic Operation/Data Transfer Manual (For GOT1000 Series) Describes methods of the GT Designer2 installation operation, basic operation for drawing and transmitting data SH-080529ENG to GOT1000 series...
  • Page 20 Manual Number Manual Name (Model Code) GOT1000 Series Connection Manual (α2 Connection) for GT Works3 Describes system configurations of the connection method applicable to GOT1000 series and cable creation JY997D39201 method (Sold separately) *1 The manual in PDF-format is included in the GT Works2, GT Designer2, GT Works3 and GT Designer3 products. A - 18...
  • Page 21 ABBREVIATIONS AND GENERIC TERMS Abbreviations and generic terms Description GT1695 GT1695M-X Abbreviation of GT1695M-XTBA, GT1695M-XTBD GT1685 GT1685M-S Abbreviation of GT1685M-STBA, GT1685M-STBD GT1675M-S Abbreviation of GT1675M-STBA, GT1675M-STBD GT1675 GT1675M-V Abbreviation of GT1675M-VTBA, GT1675M-VTBD GT1675-VN Abbreviation of GT1675-VNBA, GT1675-VNBD GT1672 GT1672-VN Abbreviation of GT1672-VNBA, GT1672-VNBD GT1665M-S Abbreviation of GT1665M-STBA, GT1665M-STBD GT1665...
  • Page 22 Abbreviations and generic terms Description Abbreviation of GT1020-LBD, GT1020-LBD2, GT1020-LBL, GT1020-LBDW, GT1020 GT1020-LBDW2, GT1020-LBLW, GT1020-LWD, GT1020LWD2, GT1020-LWL, GT1020-LWDW, GT1020-LWDW2, GT1020-LWLW GT10 Abbreviation of GT105 , GT104 , GT1030, GT1020 GT16 GOT1000 Handy GT1665HS-V Abbreviation of GT1665HS-VTBD Series Handy GT11 GT1155HS-Q Abbreviation of GT1155HS-QSBD Handy GT1150HS-Q...
  • Page 23 Option Abbreviations and generic terms Description GT05-MEM-16MC, GT05-MEM-32MC, GT05-MEM-64MC, GT05-MEM-128MC, CF card GT05-MEM-256MC, GT05-MEM-512MC, GT05-MEM-1GC, GT05-MEM-2GC, Memory card GT05-MEM-4GC, GT05-MEM-8GC, GT05-MEM-16GC SD card L1MEM-2GBSD, L1MEM-4GBSD Memory card adaptor GT05-MEM-ADPC GT16-MESB, GT15-FNB, GT15-QFNB, GT15-QFNB16M, Option function board GT15-QFNB32M, GT15-QFNB48M, GT11-50FNB, GT15-MESB48M Battery GT15-BAT, GT11-50BAT GT16-90PSCB, GT16-90PSGB, GT16-90PSCW, GT16-90PSGW,...
  • Page 24 Software Abbreviations and generic terms Description GT Works3 Abbreviation of the SW DNC-GTWK3-E and SW DNC-GTWK3-EA GT Designer3 Abbreviation of screen drawing software GT Designer3 for GOT1000 series GT Simulator3 Abbreviation of screen simulator GT Simulator3 for GOT1000/GOT900 series GT SoftGOT1000 Abbreviation of monitoring software GT SoftGOT1000 GT Converter2 Abbreviation of data conversion software GT Converter2 for GOT1000/GOT900 series...
  • Page 25 Others Abbreviations and generic terms Description Abbreviation of IAI Corporation AZBIL Abbreviation of Azbil Corporation (former Yamatake Corporation) OMRON Abbreviation of OMRON Corporation KEYENCE Abbreviation of KEYENCE CORPORATION KOYO EI Abbreviation of KOYO ELECTRONICS INDUSTRIES CO., LTD. SHARP Abbreviation of Sharp Manufacturing Systems Corporation JTEKT Abbreviation of JTEKT Corporation SHINKO...
  • Page 26 HOW TO READ THIS MANUAL Functions This manual describes functions available for the GT Designer2 Version1, GT Designer3 Version1.54G. For the added functions by the product version upgrade, refer to the list of functions added by GT Designer2 version upgrade in Appendices. Symbols Following symbols are used in this manual.
  • Page 27 MEMO A - 25...
  • Page 28 1. OVERVIEW About GOT A GOT is installed on the panel surface of a control panel or operating panel and connects to the PLC within the control panel. The GOT carries out switch operation, lamp display, data display, message display, etc. Connector for program For the display screen, two kinds of screens are available : user screen...
  • Page 29 About Manual The following manuals related to GOT 1000 series are available. Refer to each manual in accordance with the intended use. (1) Installation of the software programs Drawing Data transfer For operations from creating project data to transferring data to GOT, refer to the following manuals.
  • Page 30 (2) Installing a GOT connection to a PLC For the operations from installing a GOT to communicating with a PLC CPU, refer to the following manuals. (Included) GT15 General Description GT15 User's Manual GT11 General GOT1000 Series Purpose GT11 User's Manual Description Connection Manual GT10 User's Manual...
  • Page 31 1.1 Features (1) Improved monitoring performance and connectivity to FA devices • Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts • For GT1020 and GT1030, 3 backlight colors (green, red, orange or white, red, pink) are available for status displays •...
  • Page 32 1.2 Rough Pre-operation Procedure The outline procedure before operating GOT is shown. Start Refer to GT Designer2 Version Basic Operation/Data Transfer Manual. Install GT Designer2 or GT Designer3 in the PC. Refer to GT Designer3 Version1 Screen Design Manual (Fundamentals) Refer to GT Designer2 Version Screen Design Manual.
  • Page 33 2. SYSTEM CONFIGURATION 2.1 Overall Configuration The overall configuration of GOT is as follows. For the connection methods applicable to GOT1000 series and cable, refer to the following. GOT1000 Series Connection Manual (For GT1020, GT1030) Protective cover for oil Protective sheet GT10-LDR Memory Loader USB connecting cable...
  • Page 34 (For GT104 , GT105 Protective cover for oil Memory board Protective sheet Debug stand Personal computer Bar code reader Commercially available RS232 cable Commercially available Printer Connector conversion Serial multi-drop Panel-mounted USB port adapter connection unit extension Commercially available Debug stand is only available for GT105 The RS-232 cable vary depending on the specifications of the user's printer.
  • Page 35 6 : 8.4" 5 : 5.7" 4 : 4.7" 3 : 4.5" 2 : 3.7" GOT 1000 series GT15/GT11/GT10 For GT15 that can display 65536 colors, refer to following. GT15 User's Manual Dedicated for GT1020, GT1030 2.2 Component List 2 - 3...
  • Page 36 (2) Explanation of the option model name 90 : Dedicated for 15.0" 80 : Dedicated for 12.1" 75 : Common for 10.4", 8.4" 70 : Dedicated for 10.4" 60 : Dedicated for 8.4" 50 : Dedicated for 5.7" 40 : Dedicated for 4.7" 30 : Dedicated for 4.5"...
  • Page 37 2.2.1 GOT (GT10) Product Model name Specifications name 3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors GT1020-LBD/LWD (green/red/orange) LED backlight, 24VDC, PLC connection interface: RS-422 3.7" [160 64 dots], STN monochrome (black and white) liquid crystal, 3 colors GT1020-LBD2/LWD2 (green/red/orange) LED backlight, 24VDC, PLC connection interface: RS-232...
  • Page 38: Connection Cable

    2.2.2 Option (Optional components for GT10) PLC connection cable (Sold separately) Product name Model name Cable length Contents GT01-C10R4-8P For connecting FXCPU (MINI DIN 8 pins GT01-C30R4-8P connector) and GOT, For connecting FXCPU expansion board (MINI GT01-C100R4-8P DIN 8 pins connector) and GOT(For GT104 GT01-C200R4-8P GT105 GT01-C300R4-8P...
  • Page 39: Table Of Contents

    Product name Model name Cable length Contents GT01-C30R4-25P For connecting QnA/A/FXCPU (D-sub 25 pins connector) and GOT, GT01-C100R4-25P For connecting serial communication unit (AJ71QC24(N)-R4) and GOT(For GT104 GT01-C200R4-25P QnA/A/FXCPU GT105 GT01-C300R4-25P direct connection cable, GT10-C30R4-25P computer link RS-422 connection cable For connecting QnA/A/FXCPU (D-sub 25 pins Cable GT10-C100R4-25P...
  • Page 40 Connection cables for OMRON PLCs (For GT104 , GT105 ) (Sold separately) Product Model name Cable length Description name GT09-C30R40101-9P GT09-C100R40101-9P For connecting GOT to OMRON PLC, serial communication module, serial communication board GT09-C200R40101-9P GT09-C300R40101-9P RS-422 cable GT09-C30R40102-9P GT09-C100R40102-9P For connecting GOT to OMRON rack type host link unit, communication board GT09-C200R40102-9P GT09-C300R40102-9P...
  • Page 41 Connection cables for YASKAWA PLCs (For GT104 , GT105 ) (Sold separately) Product Model name Cable length Description name GT09-C30R40202-14P GT09-C100R40202-14P RS-422 For connecting GOT to YASKAWA PLC cable GT09-C200R40202-14P GT09-C300R40202-14P GT09-C30R20201-9P For connecting GOT to YASKAWA PLC RS-232 GT09-C30R20204-14P cable GT09-C30R20205-25P For connecting GOT to YASKAWA MEMOBUS module...
  • Page 42: And Got

    RS-232/USB conversion adaptor, cable GOT(For GT104 , GT105 Connector shape on the cable is shown in ( ). GT09-C30USB-5P is a product of Mitsubishi Electric System Service. Cable for bar code connections (Sold separately) Product name Model name Cable length...
  • Page 43 Battery (Sold separately) Product name Model name Contents For storing clock data, alarm history, recipe data and time action GT11-50BAT Battery setting value At GOT purchase, it is installed in the main unit. (For GT1030, GT104 , GT105 Bar code reader (Sold separately) Product name Model name Contents...
  • Page 44 3. SPECIFICATIONS 3.1 General Specifications Item Specifications Display section 0 to 50 Operating ambient Other than 0 to 55 (when horizontally installed), 0 to 50 (when vertically installed) temperature display section Storage ambient temperature -20 to 60 10 to 90% RH, non-condensing Operating ambient humidity 10 to 90% RH, non-condensing Storage ambient humidity...
  • Page 45 3.2 Performance Specifications • GT1020 Specifications Item GT1020-LBD/LWD GT1020-LBD2/LWD2 GT1020-LBL/LWL Type STN monochrome (white/black) liquid crystal Screen size 3.7" Resolution 64 dots (Horizontal format) Display size W86.4(3.4) H34.5(1.35) [mm](inch) (Horizontal format) Display character 16-dot standard font: 20 characters 4 lines (Horizontal format) Display Display color Monochrome (white/black)
  • Page 46 Specifications Item GT1020-LBD/LWD GT1020-LBD2/LWD2 GT1020-LBL/LWL 0.18kg (Excluding mounting Weight 0.2kg (Excluding mounting fixtures) fixtures) Compatible software package GT Designer2 Version2.43V or later/GT Designer3 Version1.01B or later • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
  • Page 47 Specifications Item GT1020-LBDW/LWDW GT1020-LBDW2/LWDW2 GT1020-LBLW/LWLW Type STN monochrome (white/black) liquid crystal Screen size 3.7" Resolution 64 dots (Horizontal format) Display size W86.4(3.4) H34.5(1.35) [mm](inch) (Horizontal format) Display character 16-dot standard font: 20 characters 4 lines (Horizontal format) Display Display color Monochrome (white/black) section Display angle...
  • Page 48 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements. Flickers may be observed depending on the display color. Please note that these dots appear due to its characteristic and are not caused by product defect.
  • Page 49 • GT1030 Specifications Item GT1030-LBD2/LWD2/ GT1030-LBD/LWD/HBD/HWD GT1030-LBL/LWL/HBL/HWL HBD2/HWD2 Type STN monochrome (white/black) liquid crystal Screen size 4.5" Resolution 96 dots (Horizontal format) Display size W109.42(4.3) H35.98(1.41) [mm](inch) (Horizontal format) 16-dot standard font: 36 characters 6 lines (Horizontal format) Display character 12-dot standard font: 48 characters 8 lines (Horizontal format) Display...
  • Page 50 Specifications Item GT1030-LBD2/LWD2/ GT1030-LBD/LWD/HBD/HWD GT1030-LBL/LWL/HBL/HWL HBD2/HWD2 External dimensions W145(5.7) H76(2.99) D29.5(1.16) [mm](inch) (Horizontal format) Panel cutting dimensions W137(5.39) H66(2.59) [mm](inch) (Horizontal format) 0.28kg Weight 0.3kg (Excluding mounting fixtures) (Excluding mounting fixtures) • GT1030-L L • GT1030-L D/L D2 GT Designer2 Version2.97B or later/ GT Designer2 Version2.58L or later/ GT Designer3 Version1.01B...
  • Page 51 Specifications Item GT1030-LBDW/LWDW/ GT1030-LBDW2/LWDW2/ GT1030-LBLW/LWLW/ HBDW/HWDW HBDW2/HWDW2 HBLW/HWLW Type STN monochrome (white/black) liquid crystal Screen size 4.5" Resolution 96 dots (Horizontal format) Display size W109.42(4.3) H35.98(1.41) [mm](inch) (Horizontal format) 16-dot standard font: 36 characters 6 lines (Horizontal format) Display character 12-dot standard font: 48 characters 8 lines (Horizontal format) Display color...
  • Page 52 Specifications Item GT1030-LBDW/LWDW/ GT1030-LBDW2/LWDW2/ GT1030-LBLW/LWLW/ HBDW/HWDW HBDW2/HWDW2 HBLW/HWLW Buzzer output (a buzzer that sounds Single tone (LONG/SHORT/OFF adjustable) when touch keys are pressed) Environmental protective structure Equivalent to IP67 (JEM1030) (front section) (Horizontal format) External dimensions W145(5.7) H76(2.99) D29.5(1.16) [mm](inch) (Horizontal format) Panel cutting dimensions W137(5.39) H66(2.59) [mm](inch) (Horizontal format)
  • Page 53 • GT104 Specifications Item GT1045-QSBD GT1040-QBBD Type STN color liquid crystal STN monochrome (white/blue) liquid crystal Screen size 4.7" Resolution 240 dots (Horizontal format) Display size W96(3.77) H72(2.83) [mm](inch) (Horizontal format) 16-dot standard font: 40 characters 15 lines (Horizontal format) Display character 12-dot standard font: 53 characters 20 lines (Horizontal format)
  • Page 54 • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements. Flickers may be observed depending on the display color. Please note that these dots appear due to its characteristic and are not caused by product defect.
  • Page 55 • GT105 Specifications Item GT1055-QSBD GT1050-QBBD Type STN color liquid crystal STN monochrome (white/blue) liquid crystal Screen size 5.7" Resolution 240 dots (Horizontal format) Display size W115(4.53) H86(3.39) [mm](inch) (Horizontal format) 15 lines (Horizontal format) 16-dot standard font: 40 characters Display character 12-dot standard font: 53 characters 20 lines (Horizontal format)
  • Page 56 Specifications Item GT1055-QSBD GT1050-QBBD Panel cutting dimensions W153(6.03) H121(4.77) [mm](inch) (Horizontal format) Weight 0.7kg (Excluding mounting fixtures) Compatible software package GT Designer2 Version2.90U or later/GT Designer3 Version1.01B or later • Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
  • Page 57 3.3 Power Supply Specifications • GT1020, GT1030 Specifications GT1020-L GT1030-L D GT1030-L GT1020-L L GT1020-L Item GT1020-L GT1030-L DW GT1030-L GT1030-L L GT1030-L GT1020-L GT1030-H D GT1030-H GT1030-H L GT1030-H GT1020-L GT1030-H DW GT1030-H 5VDC (±5%), Input power supply voltage 24VDC (+10% -15%), ripple voltage 200mV or less supplied from the PLC Fuse (built-in, not exchangeable)
  • Page 58 4. PART NAME 4.1 Front Panel 4.1.1 GT1020, GT1030 1) 2) Name Specifications Displays the utility screen and the user creation screen. Display screen GT1020 : 160 64 dots, STN monochrome (white/black) liquid crystal GT1030 : 288 96 dots, STN monochrome (white/black) liquid crystal Touch key For operating the touch switches in the utility screen and the user creation screen 4.1.2...
  • Page 59 4.1.3 GT105 1) 2) Name Specifications Displays the utility screen and the user creation screen. Display screen GT1055-QSBD : 320 240 dots, STN color liquid crystal GT1050-QBBD : 320 240 dots, STN monochrome (white/blue) liquid crystal Touch key For operating the touch switches in the utility screen and the user creation screen Green light : Power is supplied Orange light : Screen saving (At backlight off) POWER LED...
  • Page 60 4.2 Back Panel 4.2.1 GT1020-L (Hardware version A to D) INPUT 24VDC (FG) RS-422 RS-232 (Hardware version E or later) 4 - 3 4.2 Back Panel 4.2.1 GT1020-L[ ]D/L[ ]DW...
  • Page 61 Terminating resistor selector of RS422/485 (TERM.) (330 /OPEN/110 ) (At factory shipment: 330 ) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4.2 Back Panel 4 - 4 4.2.1 GT1020-L[ ]D/L[ ]DW...
  • Page 62 5) Hole for unit installation fitting (4 holes at the top and bottom) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4 - 5 4.2 Back Panel 4.2.2 GT1020-L[ ]D2/L[ ]DW2...
  • Page 63 4) Hole for unit installation fitting (4 holes at the top and bottom) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4.2 Back Panel 4 - 6 4.2.3 GT1020-L[ ]L/L[ ]LW...
  • Page 64 4.2.4 GT1030-L DW/H (Hardware version A) (Hardware version B or later) Battery cover opened 4 - 7 4.2 Back Panel 4.2.4 GT1030-L[ ]D/L[ ]DW/H[ ]D/H[ ]DW...
  • Page 65 8) Terminating resistor selector switch (TERM.) (330 /OPEN/110 ) (At factory shipment: 330 ) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4.2 Back Panel 4 - 8 4.2.4 GT1030-L[ ]D/L[ ]DW/H[ ]D/H[ ]DW...
  • Page 66 (The project data is stored in the built-in flash memory.) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4 - 9 4.2 Back Panel 4.2.5 GT1030-L[ ]D2/L[ ]DW2/H[ ]D2/H[ ]DW2...
  • Page 67 (The project data is stored in the built-in flash memory.) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4.2 Back Panel 4 - 10 4.2.6 GT1030-L[ ]L/L[ ]LW/H[ ]L/H[ ]LW...
  • Page 68 Terminating resistor selector of RS422/485 12) Terminating resistor selector switch (330 /OPEN/110 ) (At factory shipment: 330 ) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4 - 11 4.2 Back Panel 4.2.7 GT1045-QSBD/GT1040-QBBD...
  • Page 69 Terminating resistor selector of RS422/485 (TERM.) (330 /OPEN/110 ) (At factory shipment: 330 ) For the connection to the controller (PLC) or PC, refer to the following. GOT 1000 Series Connection Manual 4.2 Back Panel 4 - 12 4.2.8 GT1055-QSBD/GT1050-QBBD...
  • Page 70 Products that the EMC Directive applies to are marked with the CE mark logo. Authorized representative in Europe • This product is designed for use in industrial applications. • Authorized Representative in the European Community: Mitsubishi Electric Europe B.V. Gothaer Str. 8, 40880 Ratingen, Germany 5.2.1 Requirements for Conformance to EMC Directive The EMC Directive specifies that products placed on the market must "be so constructed that they do not...
  • Page 71 (ESD,RF electromagnetic field, EFTB, Surge, RF conducted disturbances and Power frequency magnetic field) For more details please contact the local Mitsubishi Electric sales site. About models applicable to the EMC Directive The following table lists the modules compliant with the EMC Directive.
  • Page 72 About the cable used (1) General notes on the use of communication cables Any device which utilizes a data communication function is susceptible to the wider effects of local EMC noise. Therefore, when installing any communication cables care should always be taken with the routing and location of those cables.
  • Page 73 6. INSTALLATION WARNING MOUNTING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT to/from the panel. Not doing so can cause the unit to fail or malfunction. Be sure to shut off all phases of the external power supply used by the system before mounting or removing the memory board on to/ from the GOT.
  • Page 74 6.1 Control Panel Inside Dimensions for Mounting 6.1.1 GT1020 Mount the GOT onto the control panel while considering the following control panel inside dimensions. Horizontal format 23(0.9") 80(3.14") or more 104(4.09") (0.37") (0.15") Mounting (0.39") (0.39") 3(0.11") 76(2.99") fixtures INPUT 24VDC (FG) RS-422...
  • Page 75 6.1.2 GT1030 Mount the GOT onto the control panel while considering the following control panel inside dimensions. Horizontal format 136(5.35") Mounting fixtures (0.37") 80(3.14") or more 25(0.98") (0.39") (0.39") (0.62") 84(3.3") (0.17") RS-232 cable for connecting personal computer 84(3.3") Unit: mm(inch) 25.5(1") to 28.5(1.12") (0.66") (0.39") (0.39")
  • Page 76 6.1.3 GT104 Mount the GOT onto the control panel while considering the following control panel inside dimensions. Horizontal format 129(5.07") (1.57") Unit: mm(inch) Vertical format (If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.) 121(4.76") 102(4.01")
  • Page 77 6.1.4 GT105 Mount the GOT onto the control panel while considering the following control panel inside dimensions. Horizontal format 152 (5.99") (1.19") Unit:mm(inch) Vertical format (If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.) 140 (5.52") 120 (4.73")
  • Page 78 6.2 Panel Cutting Dimensions 6.2.1 Panel cutting dimensions Cut holes in the following dimensions on the panel. A space of top and bottom is required to allow for the attachment of mounting fixtures. • Horizontal format • Vertical format Unit: mm(inch) Unit: mm(inch) A [mm] (inch) B [mm] (inch)
  • Page 79 6.3 Mounting Position 6.3.1 Mounting position When mounting the GOT, the following clearances must be maintained from other structures and devices. Horizontal format (GT1020, GT1030) Installation Environment In the presence of radiated-noise or 50 mm (1.97”) 50 mm (1.97”) 50 mm (1.97”) 80 mm (3.14”) heat-generating equipment nearby or more...
  • Page 80 Vertical format (GT1020, GT1030) Installation Environment In the presence of radiated-noise or 50 mm (1.97”) 50 mm (1.97”) 50 mm (1.97”) 80 mm (3.14”) heat-generating equipment nearby or more or more or more or more 50 mm (1.97”) or more 20 mm (0.79”) 20 mm (0.79”) In the absence of radiated-noise or...
  • Page 81 6.4 Control Panel Temperature and Mounting Angle 6.4.1 Control panel temperature and mounting angle When mounting the main unit to a control panel or similar fixture, set the GOT display section as shown below. Horizontal installation When the temperature inside the control panel is 40 to 55 , the mounting angle should be in the range from 60 to 105 degrees.
  • Page 82 6.5 Installation Procedure 6.5.1 Installation procedure The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. Cautions on the installation panel Refer to "Section 6.2 Panel Cutting Dimensions" for the panel cutting dimensions and panel thickness.
  • Page 83 Inserting into the panel face Insert the GOT from the front side of the panel. (Right drawing is the example of lateral format.) Mounting hole Fixing the GOT 1) Insert the hooks on the mounting fittings (supplied) into the mounting holes on the GOT unit. 2) Slide the mounting fittings to the back end.
  • Page 84 7. WIRING WARNING WIRING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions. Please make sure to ground FG terminal of the GOT power supply section by applying 100 or less which is used exclusively for the GOT.
  • Page 85 7.1 Power Supply Wiring Connect the power supply to the power terminals on the back panel of the GOT. Use a specified size power supply wire to prevent voltage drop, and tighten the terminal screws firmly to a specified torque. Do not exceed the number of wires that are allowed to be connected.
  • Page 86 7.1.2 Cable types and wire end processing (GT105 Use 0.75mm or thicker cables to avoid voltage drop and tighten the terminal screw with the specified torque securely. Terminal screws should be tightened to between 0.5 to 0.8 N•m. Terminal screws must be secured to prevent a loose connection thus avoiding a malfunction.
  • Page 87 7.1.4 Wiring example (GT104 INPUT 24V DC +10% DC24V -15% Class D grounding Tightening torque for the power terminals 0.22 to 0.25 N•m 7.1.5 Wiring example (GT105 INPUT 24V DC +10% DC24V -15% Class D grounding Tightening torque for the power terminals 0.5 to 0.8 N•m 7.1 Power Supply Wiring 7 - 4...
  • Page 88 7.1.6 GOT’s ground Grounding the GOT and other devices Make sure to carry out the followings for grounding. Except 5V power supply type. • Carry out the independent grounding if possible. Provide class D (class 3) grounding. (Ground resistance must be 100 or less.) •...
  • Page 89 7.1.7 The cause of malfunctions related wiring/Remedy Grounding of the GOT may cause electric potential difference and noise interference, which may result in GOT malfunctions. These problems may be resolved by taking the following measures. Wiring path of the GOT's ground cable and power line Bundling the GOT's ground cable and power line together can cause interference noise, which may result in malfunctions.
  • Page 90 • Remedy 1 (Refer to the figures Remedy 1-1 and 1-2 below.) If the electric potential difference between the ground cable and the panel that houses the GOT is creating problems, connect the ground cable to the panel also. If the wiring method as shown in Remedy 1-1 is not feasible, follow Remedy 1-2. Connection cable Connection cable Ground cable from...
  • Page 91 7.2 Wiring inside and outside the panel 7.2.1 Wiring inside Run power lines, servo amplifier drive wires, and communication cables so that they do not cross each other. Noise interference that is generated by cables that cross each other may cause malfunctions. Surge suppressors are an effective way to filter out surge noise that is generated from no fuse breakers (NFB), electromagnetic contactors (MC), relays (RA), solenoid valves, and induction motors.
  • Page 92 7.2.3 Attaching surge killers to control equipment If communication errors happen in synch with the on/off signals from certain control equipment (referred to as "load" hereafter) such as no fuse breakers, electromagnetic contactors, relays, solenoid valves, and induction motors, surge noise interference is suspected. If this problem happens, keep the ground cable and communication cable away from the load.
  • Page 93 8. OPTION 8.1 Protective Sheet The protective sheet is used to protect the operation surface from damage or dirt when the touch key of GOT display section is operated. For the GOT, a protective film is pasted on the display at factory shipment. Remove the film when the installation of the GOT is completed.
  • Page 94 8.1.2 Installing procedure If a protective sheet is on the GOT, peel off the protective sheet from the bottom-right corner of the GOT display section, and clean the GOT surface. Peel the release paper from the back of the new protective sheet, and attach its adhesive side to the GOT display section.
  • Page 95 GT1020, GT1030 Installing port USB cable for connecting a personal computer (Mitsubishi Electric System Service Co, LTD) Conversion adaptor 8.2.1 Shape, dimensions, and names of adaptor components The shape, dimensions, and names of the RS-232/USB conversion adaptor are shown in the figures below.
  • Page 96 8.2.2 Installing procedure Turn off the GOT power. Connect the USB mini connector on the GT09-C30USB-5P USB cable to the RS-232/USB conversion adaptor. Connect the RS-232 connector on the RS-232/USB conversion adaptor to the GOT. Connect the USB connector on the GT09-C30USB-5P USB cable to the PC. Turn on the GOT power.
  • Page 97 8.2.3 Driver installation Procedure for installing the driver is explained below. Windows XP installation follows. • Windows 98, Windows 98SE, Windows Millennium Edition, Windows 2000, Windows Windows Vista and Windows 7/8 the installation method will vary. Installation of the driver is canceled during the following process, the installation is not carried out correctly. If the installation is canceled, uninstall the driver and install again.
  • Page 98 The screen on the left is displayed. (Only in Windows Click [ Continue Anyway ]. The screen on the left is displayed. Click [ Finish ]. The installation of the USB driver software will finish. • If Windows 98, Windows 98SE or Windows Millennium Edition is used, installation of the USB Serial Port software begins, and ends automatically.
  • Page 99 The screen of is displayed. (Only in Windows Click [ Continue Anyway ]. The screen on the left is displayed. Click [ Finish ]. The installation of the USB Serial Port software will finish. The CD-ROM (USB driver software) can be removed from the personal computer at this time.
  • Page 100 Windows Vista Installation method of driver software (1) Two types of drivers are required to be installed. Make sure to install the two types of drivers by the following procedure. (2) When the included CD-ROM is not used For GT Designer2 Version2.109P or later and GT Designer3 Version1.17T or later, the driver software is stored in the following folder.
  • Page 101 Installation of the driver software is started. When installation of the USB driver software is finished, the COM port driver software is installed continuously. The screen on the left is displayed. Click [ Don’t search online ]. When the message [ Insert the disc that came with your USB Serial port ] is displayed, insert the CD- ROM into the personal computer.
  • Page 102 Windows 7/8 (32bits) Installation method of driver software (1) Two types of drivers are required to be installed. Make sure to install the two types of drivers by the following procedure. (2) When the included CD-ROM is not used For GT Designer2 Version2.109P or later and GT Designer3 Version1.17T or later, the driver software is stored in the following folder.
  • Page 103 The warning message on the left is displayed. Select [ Insert this driver software anyway ]. Installation of the driver software is started. When installation of the USB driver software is finished, the COM port driver software is installed continuously. Right-click [ USB Serial Port ] in the Device Manager.
  • Page 104 Windows 7/8 (64bits) Installation method of driver software (1) Two types of drivers are required to be installed. Make sure to install the two types of drivers by the following procedure. (2) When the included CD-ROM is not used For GT Designer3 Version1.31H or later, the driver software is stored in the following folder.
  • Page 105 The screen on the left is displayed. Select [ Change settings ]  [ Update Driver ]. When the driver software search method selection screen is displayed, select [ Browse my computer for driver software ]. When installing the drivers from the included CD-ROM, set the CD-ROM in a personal computer. The search location specification screen is displayed.
  • Page 106 When installation of the USB driver software is finished, the COM port driver software is installed continuously. Select [ Control Panel ]  [ Hardware and Sound ]  [ Devices and Printers ] to display the screen on the left. Right-click the GT10-RS2TUSB-5S, and select [ Properties ].
  • Page 107 When the driver software search method selection screen is displayed, select [ Browse my computer for driver software ]. The search location specification screen is displayed. • Installing from the CD-ROM Specify the CD-ROM drive [ \Win2K ] as the search location, and click [ Next ]. •...
  • Page 108 8.2.4 Method for uninstalling driver The procedure for uninstalling the driver is explained below. A Windows XP example follows. When the driver softwares for FX-USB-AW/FX -USB-BD and GT10-RS2TUSB-5S are installed, uninstalling one of these driver softwares may cause the other not to function properly.
  • Page 109 8.3 Battery The battery backs up clock data, alarm history and recipe data. At factory shipment, a battery is built in the GT1030, GT104 , GT105 . For GT1020, a battery cannot be used. (Data is saved by the internal flash ROM.) 8.3.1 Applicable battery The following battery is applicable for GT1030, GT104 , GT105 .
  • Page 110 8.3.3 Battery replacement procedure Replace battery periodically at intervals of 4 to 5 years as reference. Turn the GOT power off. Open the back cover of the GOT. Remove the old battery from the holder. Back cover Back cover Back cover Holder Holder Connector...
  • Page 111 Example nameplate (manufacture's serial number 1010001) GRAPHIC OPERATION TERMINAL GT1030-LBD MODEL IN 20.4 26.4VDC POWER 2.2W MAX 1010001 AA MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN Actual product nameplate differs <Jan., 2010 or later> from the example shown above. 7-digit Control number Month (example: Jan.).
  • Page 112 8.4 Memory loader GT10-LDR memory loader is the memory transfer module that reads/writes the data to GT1020, GT1030 or between a PC (GT Designer2 Version2.77F or later, GT Designer3 Version1.01B or later) and GT10-LDR. When using the memory loader, driver installation, communication port setting is required. Refer to the following manual for details about driver installation.
  • Page 113 8.4.1 Part name Name Specifications POWER LED LED to show power status SET/RUN LED LED to show that the settings are being checked/the transfer is running ERROR LED LED to show error status RD/WR selection switch Switch to select read/write direction Data selection switch Switch to select the data to be transferred Switch to determine the transfer direction and the data to be transferred, and to...
  • Page 114 8.4.2 Function specification Standard monitor OS Standard monitor OS Font data Font data Communication driver Communication driver Project data Project data Project data Standard monitor OS Resource data Communication driver GT1020, GT1030 Project data Resource data Memory loader (GT Designer2, GT Designer3) : Available to transfer : Unavailable to transfer Transfer data...
  • Page 115 *2 : Ver.01.11.00 or later of the standard monitor OS of the GT10 is applicable. Supported by the memory loader manufactured in November 2008 or later. When transferring the font data with the memory loader manufactured before November 2008, upgrade the version of memory loader OS from GT Designer2 (Ver.2.91V or later).
  • Page 116 8.5 Memory board GT10-50FMB type memory board is used for transferring the OS, project data or font data to the GOT (for GT104 , GT105 only). 8.5.1 Applicable memory board The following memory board is applicable for GT104 , GT105 . Model Contents GT10-50FMB...
  • Page 117 Removing Turn the GOT power off. Pull up the memory board vertically and remove it. Memory board Memory board For GT105 For GT104 Precautions for installing/removing the memory board When installing or removing the memory board, be sure to power off the GOT main unit.
  • Page 118 8.6 Stand Stand is used to fix the GOT (For GT105 ) to standing status in order to debug the monitor screen data easily. 8.6.1 Applicable stand The following stand is applicable for GT105 . Product name Model Contents Stand GT05-50STAND Stand for 5.7"...
  • Page 119 8.7 Protective cover for oil Use of the protective cover for oil improves oil resistance, and chemical resistance of the GOT. 8.7.1 Applicable protective cover for oil The following protective covers for oil are applicable to the GT10 Product name Model Description GT10-20PCO...
  • Page 120 The oil cover was hung and the edge of the oil cover is The corner on the left is hung and the oil sequentially obtained and obtain the oil cover to cover rubber cover is hung from A side to D side on the starting point sequentially.
  • Page 121 Confirm the hardware version with the products rating plate. GRAPHIC OPERATION TERMINAL GT1030-LBD MODEL IN 20.4 26.4VDC POWER 2.2W MAX 710001 AA Hardware version MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN 8.8 Serial Multi-Drop Connection Unit 8 - 29 8.8.1 Serial multi-drop connection unit...
  • Page 122 8.8.2 Applicable serial multi-drop connection unit The following serial multi-drop connection unit is applicable. Model Contents GT01-RS4-M For GOT multi-drop connection 8.8.3 Part name • Protective cover is installed • Protective cover is removed 2- 4.5 Name Specifications Installation hole for the main unit Installation hole POWER Lit in green when the power is properly supplied.
  • Page 123 8.8.4 Installation Installed with DIN rail Install the multi-drop connection module with its hook (1 place) using the DIN rail. • Applicable DIN rail DIN46277 (width: 35mm) (Install the DIN rail with screws at intervals of 150mm.) Directly installed to panel Install the multi-drop connection module to the panel using 4.5mm holes (2 places).
  • Page 124 Confirm the hardware version with the products rating plate. GRAPHIC OPERATION TERMINAL GT1030-LBD MODEL IN 20.4 26.4VDC POWER 2.2W MAX 710001 AA Hardware version MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN 8.9.1 Applicable connector conversion adapter The following connector conversion adapter is applicable. Model Contents GT10-9PT5S For GOT multi-drop connection 8.9.2...
  • Page 125 8.10 Panel-Mounted USB Port Extension The panel-mounted USB port extension GT10-C10EXUSB-5S is an extension cable having the waterproof function. 8.10.1 Applicable panel-mounted USB port extension The following panel-mounted USB port extension is applicable for GT104 and GT105 Model Contents GT10-C10EXUSB-5S Panel-mounted USB port extension 8.10.2 Part name The part names of the panel-mounted USB port extension are shown in the figures below.
  • Page 126 Cautions on Installation of panel-mounted USB port extension (1) Run power lines, servo amplifier drive wires, and panel-mounted USB port extension so that they do not cross each other. (2) Keep the panel-mounted USB port extension away from any equipment which can become noise source.
  • Page 127 9. UTILITY FUNCTION The utility functions allow the user to confirm the settings for communication interface, screen display, operation methods, and clock data as well as OS information. GT10 is factory-installed with the Standard monitor OS and BootOS. (An installation of the Standard monitor OS or BootOS is not required to use the utility functions.) 9.1 Utility Function List The items in the following list can be set/operated on the utility screens.
  • Page 128 Functions overview Item GT1020 GT1030 GT104 GT105 Sets the clock (clock Time setting Sets the clock (clock data) on the PLC, Display of battery status data) on the PLC OS information Displays the OS (Standard monitor OS, BootOS) and communication driver versions Clear data Clears the project data and resource data on the GOT Data...
  • Page 129 9.2 Utility Display 9.2.1 Display operation of main menu The following four types of operation can display the main menu. (The utility function windows appear in the horizontal format, and this format cannot be changed.) (1) When project data is undownloaded After the GOT is turned on, a dialog box for notifying of absence of project data is displayed.
  • Page 130 (3) When touching special function switch If you touch the special function switch (utility) while user-created screen is displayed, the main menu is displayed. The special function switch (utility) can be set as a touch switch that is displayed on a user-created screen by drawing software.
  • Page 131 Remark Lock the utility display by password. When a password is set on the GOT using drawing software, a password dialog box is displayed when trying to access the main menu of the utility display. (The password setting option in drawing software is located in the common menu.) Enter the password that has been set.
  • Page 132 9.2.2 Utility basic configuration The basic configuration of the screen is as follows. Main Menu The menu items that can be selected from the GOT utility are displayed. GT1020 GT104 , GT105 Use the buttons to select an item from the menu. Touching a menu item in the main menu will display the setting screen or following selection screen for the item.
  • Page 133 GT1020 GT104 , GT105 Title display Close/Return button Title display Close/Return button Scroll button Menu item Main item Scroll button (1) Title display The screen title name is displayed in title display part. (2) Close/Return button When a middle screen of the layers is displayed, if the (Close/return) button in the right corner of screen is touched, returns to the previous screen.
  • Page 134 10. LANGUAGE SETTING (Language) 10.1 Display language setting 10.1.1 Display language setting function This function allows display language selection. The items which can be set are shown below. Item Contents Setting range Display language in which the utility functions and dialog windows Japanese/English Language are displayed can be selected or confirmed in this menu...
  • Page 135 Switching the display language of the utility by devices Any device can be used for switching the display language of the utility. For details, refer to the following. GT Designer3 Version1 Screen Design Manual (Fundamentals) When using devices to switch the display language of the utility, it does not change even if the display language is switched from the GOT utility screen.
  • Page 136 11. COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) The [Communication Setting] menu has the [Standard I/F], [Data Transfer], [Communication Monitor], and [Keyword] menus. The [Standard I/F] menu sets the information about the channel numbers, controller name, and detailed settings of the communication parameters that are allocated to the communication interfaces by drawing software.
  • Page 137 11.1.3 Display contents of standard I/F Described below are the display items on the standard I/F setting menu and their functions. Display item column button <For GT1020> <For GT1030> Communication interface selection button button Standard interface display BOX Driver display BOX Channel No.
  • Page 138 (2) Standard interface display BOX Displays communication interface. (a) GT1020, GT1030 The standard interface includes the following two types. Standard I/F-1: For communication with PLC, microcomputer and other equipment Standard I/F-2: For communication with PC (drawing software), modem, bar code reader and transparent Standard I/F-1 Standard I/F-2...
  • Page 139 (c) GT105 The standard interface includes the following three types. Standard I/F-1(RS-422): For communication with PLC, microcomputer and other equipment Standard I/F-2(RS-232): For communication with PLC, PC (drawing software), modem, other equipment, bar code reader and transparent Standard I/F-3(USB): For communication with PC (drawing software) and transparent [GOT back panel] Standard I/F-3 (USB) Standard I/F-1 (RS-422)
  • Page 140 button Displays the driver setting screen. Select the driver to use on the driver setting screen. button is displayed in the following cases. • When setting the "ch9" to standard I/F-2. button Displays the AT command setting screen. Set the AT command to use for initializing the modem on the AT command setting screen. button is displayed in the following case.
  • Page 141 11.1.4 Detail information setting operation Touch Standard I/F-1 driver display box in the Standard I/F setting window. Touch [Driver display BOX]. The screen jumps to the detailed information screen and the communication parameter will appear. Use the buttons to toggle through the items when there are multiple items to be set.
  • Page 142 When the button is touched, the settings are fixed and the window returns to the previous one. Therefore, touch the button. Touch the button to display the window confirming whether to save the settings. Touch the button to save the settings and restart.
  • Page 143 Precautions for communication between GOT and connected devices (1) Installing [Communication driver] and downloading [Communication Settings] To perform communication with the connected device, the following actions are necessary. 1) Installing [Communication driver] (Up to 1, OS installation) The driver for [MELSEC-FX] is factory-installed. Install the communication driver to connect a controller other than a MELSEC-FX.
  • Page 144 11.1.5 Channel setting operation Channel number setting operation Touch the channel No. specification menu box to be set. Touch When the channel setting window appears, select the channel number. Touch When the channel number is selected, the settings are fixed and the window returns to the previous one.
  • Page 145 11.1.6 Driver setting operation Driver setting operation Touch button to bring up the driver setting window. Touch [Drv] The available driver names are displayed on the driver setting screen. Select the driver to use. Touch When the driver is selected, the display returns to the standard IF setting screen.
  • Page 146 11.1.7 AT command operation AT command operation Touch button to bring up the AT command setting window. Touch [AT] The AT command, set in the drawing software or in the utility of the main unit, is displayed. When editing the AT command, touch button to display the ASCII window.
  • Page 147 MODEL Example H/W version: H IN 20.4 26.4VDC POWER 2.2W MAX Boot OS version: AD 710001 AA BootOS Version MITSUBISHI ELECTRIC CORPORATION Rating plate: HD MADE IN JAPAN 11.1 Standard I/F Setting 11 - 12 11.1.8 Installing of communication driver...
  • Page 148 11.2 Data Transfer 11.2.1 Data transfer functions Function Contents Displays the screen for transferring project data between the PC and GOT. If any device other than the PC is allocated to the interface for communication Data transfer screen display with PC, the GOT will not be able to communicate with the PC, except when the Data transfer window is on the screen.
  • Page 149 11.2.3 Data transfer display [Waiting] on the data transfer screen will change to [Transferring...] when project data are transferred from drawing software. At the completion of data transfer, the user-created screen will appear. Transfer of project data from drawing software Completion of data transfer User-created screen Transfer of project data...
  • Page 150 11.3 Communication Monitor 11.3.1 Communication Monitor functions Function Contents Communication port-selection Displays the connection status of Standard I/F-1 and I/F-2 status display Communication status display Displays the communication status (SD: send, RD: receive) Communication error status display Displays an error message when a communication error occurs 11.3.2 Communication Monitor display operation Main Menu Touch...
  • Page 151 11.3.3 Screen display content Connection status of the communication ports Indicates the connection status of Standard I/F-1 and I/F-2. Listed in the table below are display items and the connection status (channel number). Display item Channel number Remarks "PLC" appears when connected to a controller (PLC or microcomputer) "BCR"...
  • Page 152 Communication error status Communication error status of each port is displayed on this screen. The table below summarizes the types and nature of the errors. Display item Action NO ERROR Communication is executed normally. The receive data is sent continuously with a short interval. ERR Ovr.
  • Page 153 11.4 Keyword 11.4.1 Keyword functions The operation related to a keyword of the FX series PLC can be performed. Function Contents Regist Keyword is registered. Delete Registered keyword is deleted. Clear Keyword protection is cancelled. Protect A keyword with cancelled protection is reactivated for protection. How to use the keyword function To use a keyword, the standard monitor OS[01.10.**] or later and the communication driver MELSEC-FX[01.06.**] or later must be installed on the GOT.
  • Page 154 11.4.3 Regist Keyword is registered. Touch Regist to display the selection " " screen for the registration. For the FX series PLC, which is not compatible with Customer Keyword, the keyword entry screen of ) is displayed. Start the operation from Touch For the Customer Keyword compatible models, refer to the manual of the PLC to...
  • Page 155 Set Registration conciliation. Touch Registration conciliation to change the setting contents. Touch All Protect Write Protect R/W Protect After setting Registration conciliation, touch the [Execute] key. The registration of the keyword is completed. Touch After the completion of the keyword registration, touch Touch 11.4 Keyword...
  • Page 156 (1) Selection availability of Registration conciliation The following table lists the PLCs that can select Registration conciliation. Settings Target PLC When keyword and 2nd keyword are When only keyword is registered registered FX PLC compatible with 2nd Registration options can be selected. keyword Registration options cannot be...
  • Page 157 11.4.4 Delete Registered keyword is deleted. Touch [Delete] to display the keyword entry screen. Touch Touch the display part of the registered keyword. Target PLC Settings FX PLC compatible with Input a keyword to be deleted. 2nd keyword Touch Input a keyword to be deleted only into FX PLC not compatible "keyword".
  • Page 158 11.4.5 Clear To access an FX PLC where a keyword has been registered, keyword protection is cancelled. Touch [Clear] to display the keyword entry screen. Touch Touch the display part of the registered keyword. Target PLC Settings FX PLC compatible with Input a keyword or customer keyword to customer keyword cancel the protection.
  • Page 159 11.4.6 Protect A keyword with cancelled protection is reactivated for protection. Keyword protection function is valid when the 2nd keyword is registered. Touch [Protect] to switch to the keyword protection status. Touch 11.4 Keyword 11 - 24 11.4.6 Protect...
  • Page 160 12. DISPLAY AND OPERATION SETTINGS (GOT SET UP) Setting screen for display and setting screen for operation can be displayed from GOT setup. In the setting screen for display and the setting screen for operation, the following settings can be set. Description Screen GT1020...
  • Page 161 12.1 Display Settings 12.1.1 Display setting functions Setting regarding display is possible. The items which can be set are shown below. Contents Items Setting range GT1020 GT1030 GT104 GT105 0 to 60 minutes The period from the user stops the touch panel operation till the screen save <At factory shipment: 0 minutes>...
  • Page 162 12.1.2 Display operation of display setting Main Menu Touch Touch [GOT setup]. Display GOT setup Touch [Display]. 12 - 3 12.1 Display Settings 12.1.2 Display operation of display setting...
  • Page 163 12.1.3 Display setting operations Screen save time Touch [Screen Save] to bring up the Display screensaver setting window. Touch [Screen save]. Touch [Time] to bring up the time setting window. Touch [Time]. Touch the time that appears on the time setting window to bring up the ten-key pad.
  • Page 164 Screen save backlight Touch [Screen Save] to bring up the screensaver Display setting window. Touch [Screen save]. Touch [Backlight] to bring up the backlight setting window. Touch [Backlight]. Touch the button to turn off/turn on the backlight. • button: Screen save, Transferring..., Backlight, Unlit •...
  • Page 165 Contrast Touch [Contrast] to bring up the setting window. Display Touch [Contrast]. Touch the [] and [+] buttons to adjust the contrast of the screen. Adjust contrast with the [−] and [+] buttons. After changing the settings, touch the button to save the changes and close the setting Touch window.
  • Page 166 Opening time Touch to bring up the [Opening time] setting Display window. Touch Touch [Opening time] to bring up the setting window. Touch [Opening time]. Touching the set time (value) can change the setting. Touch After changing the settings, touch the button to save the changes and close the setting Touch window.
  • Page 167 12.2 Operation Settings 12.2.1 Operation setting functions Setting regarding GOT operation can be set. The items which can be set are described below. Contents Function Setting range GT1020 GT1030 GT104 GT105 OFF/SHORT/LONG Buzzer volume Buzzer volume setting can be changed <At factory shipment: SHORT>...
  • Page 168 12.2.2 Display operation of operation setting Main Menu Touch Touch [GOT setup]. Operation* GOT setup Touch [Operation]. *: GT1030, GT104 , GT105 does not have [Calibration] function. 12 - 9 12.2 Operation Settings 12.2.2 Display operation of operation setting...
  • Page 169 12.2.3 Setting operation of operation Buzzer volume Operation Touch [Buzzer setting] to bring up the buzzer volume setting window. Touch [Buzzer setting]. Touch [Buzzer volume] to bring up the setting window. Touch [Buzzer volume]. Touch a setting item to change the setting. (Buzzer volume: SHORT LONG...
  • Page 170 Window move buzzer Touch [Buzzer setting] to bring up the buzzer Operation volume setting window. Touch [Buzzer setting]. Touch [Window move] to bring up the setting window. Touch [Window move]. Touch a setting item to change the setting. (Window move buzzer: Touch After changing the settings, touch the button to save the changes and close the setting...
  • Page 171 Calibration <For GT1020> Touch [Calibration] to bring up the setting Operation screen. Touch [Calibration]. Touch the "+" symbol at the top left corner. Touch Touch the "+" symbol at the bottom left corner. Touch Touch the "+" symbol at the top right corner. Touch Touch the "+"...
  • Page 172 Touch panel calibration error If touch panel calibration results in inoperability of the panel, the following message will appear. button: Returns to the touch panel calibration screen. button: Aborts calibration without saving any changes to the touch panel setting. Key reaction Touch to bring up the [Key reaction] setting Operation...
  • Page 173 Clock setting Setup the method to adjust the time between GOT data and the clock data of PLC CPU connected with GOT. Setting Contents Adjust the time of GOT clock data to the clock data of PLC CPU. Adjust Same as setting in [GOT setup] in [System Environment] of GT Designer2. Same as setting in [GOT Setup...] in [GOT Environmental Setting] of GT Designer3.
  • Page 174 Security Touch [Security] to bring up the setting window. Operation Touch [Security]. Touching [Security level] displays the password input window. Inputting the password set in the password input Touch window can change the security level. After changing the settings, touch the button to save the changes and close the setting Touch window.
  • Page 175 Utility call Touch [Utility call] to bring up the setting window. Operation Touch [Utility call]. Touch displayed on the four corners of the setting screen. The button repeats every time it is Touch bottoms to set for pressed. the Utility call key. Change the part to be set as a key position to The key position can be set to the zero point.
  • Page 176 13. CLOCK SETTINGS AND BATTERY STATUS DISPLAY (TIME SETTING AND DISPLAY) The clock data (date and time) are displayed and set in the clock setting menu. The voltage status of the built-in battery is also displayed. 13.1 Time Setting and Display 13.1.1 Time setting and display functions Time settings and displaying of the status of GOT built-in battery are possible.
  • Page 177 13.1.3 Clock setting operations Clock display Displays and sets up the clock data on the GOT. When setting the clock data, change the clock data on the GOT and controller unless the clock setting is "unused". If you fail to change the clock data on the controller, the clock data on the GOT is not changed as well.
  • Page 178 14. FILE DISPLAY (DATA) This function displays the version of the OS (Standard monitor OS, BootOS) and communication driver that are written to the GOT. Project data and resource data can be deleted with this function. 14.1 Data Storage Location The following drive name (C or D drive) is assigned to the built-in Flash Memory or SRAM on the GOT.
  • Page 179 14.2 OS Information 14.2.1 Function of OS information This function displays the version of the OS (Standard monitor OS, BootOS) and communication driver on the built-in flash memory (C drive). 14.2.2 Display operation of OS information screen Main Menu Touch Touch [Data].
  • Page 180 14.2.3 OS information operation OS information display (For GT1020) Touch the buttons to toggle through the version of the [Standard monitor OS], [Communication driver], and [BootOS]. Touch the button to close the screen. 14 - 3 14.2 OS Information 14.2.3 OS information operation...
  • Page 181 14.3 Font Data 14.3.1 Function of font data The types of fonts that are stored in the C: Built-in flash memory. 14.3.2 Display operation of font data screen Main Menu Touch Touch [Data]. Font data <For GT1020> Data Touch [Font data]. <For GT1030>...
  • Page 182 14.3.3 Font data operation Font data display (For GT1020) Touch button to switch the display of fonts that are stored in the C: Built-in flash memory. Touch the button to close the screen. 14 - 5 14.3 Font Data 14.3.3 Font data operation...
  • Page 183 14.4 Clear data 14.4.1 Clear data functions This function deletes the project data and resource data that are written to the GOT. 14.4.2 Clear data display Main Menu Touch [Data]. Touch Clear data Data Touch [Clear data]. 14.4.3 Clear data operation Touch the type of data on the screen to be deleted.
  • Page 184 14.5 GT10-50FMB 14.5.1 GT10-50FMB functions (For GT104 , GT105 only) Use the GT10-50FMB type memory board to transfer the project data or OS. Copy from the memory board to the GOT Copying from the memory board to the GOT when turning on the power to the GOT. Refer to the following.
  • Page 185 14.5.3 GT10-50FMB operation Select the copy direction. The selection mark is displayed on the side of the selected key. - GOT FMB:Copy from the GOT to the memory board Touch - FMB GOT: Copy from the memory board to the GOT After selecting the direction, touch the [OK] button.
  • Page 186 When the transfer direction is set to "GOT FMB" and the copy target is set to "OS+Projectdata" with the ver01.11.** or later of the standard monitor OS of the GOT, a window confirming the copy of the font data is displayed. Select YES/NO to decide whether to copy the font data or not.
  • Page 187 Copy is completed. Touch the ESC button to close the Touch screen. If an error occurs during copy, an error message appears. For details of error messages, refer to the following. Section 14.5.4 Error display When only the project data was copied to the GOT, touch the ESC button to restart the GOT and display the user- created screen.
  • Page 188 15. GOT DEBUG 15.1 Debug The debug includes functions to check the PLC system status and to improve troubleshooting efficiency. The following is available as the debug. Contents Items GT1020 GT1030 GT104 GT105 For a controller connected to the GOT, forcibly turning on or off devices of the controller and Device monitor changing the set value or present value are available.
  • Page 189 Checking method of OS, Communication driver version Check the version of OS or communication driver installed in GOT at [OS information] of the utility. Refer to the following for details. Section 14.2 OS Information 15.2.2 Devices that can be monitored For further information about the monitor device names that can be monitored and the scope, see the following: GT Designer2 Version...
  • Page 190 15.2.4 Display operation of device monitor Main Menu Touch Touch [Debug]. Device monitor <For GT1020> Debug Touch [Device monitor]. <For GT1030> <For GT104 , GT105 > 15 - 3 15.2 Device Monitor 15.2.4 Display operation of device monitor...
  • Page 191 15.2.5 Information displayed on the device monitor screen and key functions Device monitor screen The information displayed on the device monitor screen is described below. For GT1030 For GT104 , GT105 For GT1020 Item Description of setting Device name Displays the device name. Device No.
  • Page 192 Item Description of setting Displays the counting method when registering the counters from Counting method C200 to C255. UP: Up count mode DOWN: Down count mode Displays the reset coil state when registering the timer/counter for the FXCPU. Reset coil ON/OFF : ON : OFF 0 to 4: This item must be set only when the GOT is connected to the...
  • Page 193 15.2.6 Basic operation of device monitor The following explains basic operations of the device monitor. Debug Touch [Device monitor]. With no registered device With registered devices TEST DEC/HEX Touch Touch Touch Register devices if necessary. Execute the quick test if Switch the numerical notation of word necessary.
  • Page 194 15.2.7 Device registration The following explains the procedures for device registration. Device monitor Connecting to a Q series CPU in the multiple CPU system or QnUCPU Specify a CPU No. for the devices to be registered. Connecting to a CPU other than the Q series Touch CPU in the multiple CPU...
  • Page 195 Keyboard operations (1) Keyboard functions Ends the device registration. Select a data type. [32]: Sets to the two-word. [16]: Sets to the one-word. Device name keyboard Switches device names on the keyboard. Deletes all input numbers. Device number keyboard Ends the device registration. Registers the input device.
  • Page 196 Precautions for device registration (1) Data type Device monitor screens display the data type as shown below. • DW : 32-bit (two-word) module • Nothing displayed : 16-bit (one-word) module (2) CPU No. specification Changing the CPU No. after registering devices cancels the registration for all the devices.
  • Page 197 15.2.8 Quick test WARNING Before performing the quick test operations of device monitor (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter), read through the manual carefully and make yourself familiar with the operation method. During quick test operation, never change the data of the devices which are used to perform significant operation for the system.
  • Page 198 (1) Quick test of bit devices (Operation example) Change the status of bit device M12 from OFF to ON Touch the bit device to be switched between ON and OFF states. The device name and device number of the selected bit device are highlighted.
  • Page 199 (2) Quick test of word devices (Operation example) Change the device value of word device D200 from 43 to 100. Conditions: Data range: 16 bits, device value display format: decimal number Touch the device value to be changed. Input a device value by using the keyboard.
  • Page 200 15.3 FX List Editor (For GT104 , GT105 only) GT104 , GT105 can edit the sequence programs of the connected FXCPU using the list editor. 15.3.1 Display operation of FX list editor Main menu Touch [Debug]. FX list editor Debug Touch [FX list editor].
  • Page 201 Parameters and sequence programs are easy to maintain. You can check or partly correct, change or add FX PLC CPU parameters and sequence programs simply by operating keys. You can easily edit sequence programs without preparing any peripheral unit other than the GOT. (Example of changing sequence program commands) Changed X000...
  • Page 202 15.3.2 Specifications System configuration This section describes the system configuration of the MELSEC-FX list editor. For further information about communication units and cables for each connection form, see the following. GOT1000 Series Connection Manual Controllers that can be edited with the MELSEC-FX list editor Target controller FXCPU Connection forms...
  • Page 203 Functions list and monitor conditions The following shows the memory that can be monitored by the MELSEC-FX list editor and the FX PLC status conditions. : Can be monitored : Can be monitored under certain conditions : Cannot be monitored) Memory that can be monitored EEPROM FX PLC...
  • Page 204 15.3.4 Precautions (1) Inapplicable GOT The FX list editor function cannot be used with the GT1030 and GT1020. (2) Using other peripheral equipment for sequence program/parameter change When using the MELSEC-FX list editor, do not change programs or parameters in the PLC CPU from other peripheral equipment.
  • Page 205 15.3.5 Display Outline until the start The following explains the outline until the operation screen of MELSEC-FX list editor is displayed. Start Turn on the power to the GOT. Starting from the special function Starting from the switch (MELSEC-FX list editor) utility set in the project data Display the utility.
  • Page 206 Change screens This section describes how to change the screen. Start Utility Main Menu user-created monitor screen MORE MORE [PLC diagnostics] [Parameter setting] [Keyword setup] [List Monitor] With setting special function switches (FX list monitor), the list monitor can be started on the monitor screen. When the list monitor is started on the monitor screen, the list editor cannot be used.
  • Page 207 15.3.6 Operation Procedures This section describes the contents of the MELSEC-FX list editor and the key functions displayed on the screen. Key arrangement and a list of key functions The arrangement and functions of the keys displayed on the MELSEC-FX List Editor window are described below.
  • Page 208 Key functions The table below shows the functions of the keys that are used for the operation on the MELSEC-FX list editor screen. Function Selects a mode for MELSEC-FX list editor. ( SubSection 15.3.7 Selection and operation of modes) Displays the PLC diagnostics, parameter setting, and keyword selection menu. Switches between command keyboard 1 and command keyboard 2.
  • Page 209 15.3.7 Selection and operation of modes The MELSEC-FX list editor has four modes: READ, WRITE, INSERT, and DELETE. Select an appropriate mode for the intended operation. For more information on the mode to select, refer to the function operations from subsection 15.3.8 onward. How to change modes Touch the button.
  • Page 210 15.3.8 Sequence program display Sequence programs are read from the FX PLC to the GOT and displayed. There are two displaying methods: specifying the step number, and scrolling one screen at a time. Display using cursor keys (1) Operation Scroll with (2) Example Scroll one line upward or downward.
  • Page 211 Display scrolling one screen at a time (1) Operation MODE (Read mode) (2) Example Displaying with scrolling one screen at a time. < WRITE > MODE Set the READ mode. < READ > Displaying with scrolling K 200 one screen at a time. D 58 15.3 FX List Editor (For GT104[ ], GT105[ ] only) 15 - 24...
  • Page 212 15.3.9 Searching commands and devices Displays a command or device by searching it in sequence program from Step 0. Command search (1) Operation Select the command Input the device name and MODE device number. to search for. (Read mode) MORE *1 If the command you want to search for is not on the keyboard, touch the key to switch to the other keyboard.
  • Page 213 Device search (1) Operation Input the device name and MODE device number. (Read mode) *1 After the search results are displayed, you can continue searching with the same conditions by touching the key. Touching any key other than the key ends the search. (2) Example Searching for LD M8000.
  • Page 214 15.3.10 Writing commands Writes a sequence program to the FX PLC. (Overwrite/Insert) Writing basic commands (1) Operations (a) Inputting command only (Ex.: ANB, ORB command etc.) Input the command Stop the FX PLC MODE For overwriting: (WRITE mode) For insertion: (INSERT mode) (b) Inputting command and device (LD, AND commands etc.) Input the command Stop the FX PLC...
  • Page 215 (b) Inputting LD X000 Stop the FX PLC 0 NOP 1 NOP < READ > 2 NOP 3 NOP MODE Set the WRITE or < WRITE > 0 LD INSERT 1 NOP mode. 2 NOP 3 NOP With , move the cursor to the position to overwrite/insert the command.
  • Page 216 Writing applied instructions (1) Operations Applied instruction number Stop the FX PLC MODE For overwriting: (WRITE mode) For insertion: (INSERT mode) Input the device name and device number. (double word command) and (pulse execution format command) can also be input after the applied instruction number is input. Inputting in the order is also possible.
  • Page 217 15.3.11 Changing operands, set values Changes the operand section of an applied instruction and OUT (T, C) command set value. Operation Input the device name and device number Stop the FX PLC MODE (Read mode) *1 For decimal numbers, input K, then the number. For hexadecimal numbers, input H, then the number.
  • Page 218 15.3.12 Deleting commands Deletes one command at a time from a sequence program. Operation Stop the FX PLC MODE Move the cursor to the command to be deleted. (DELETE mode) When moving the cursor to the position where the command is to be deleted. Place the cursor on the command line (the line on which the step number is displayed).
  • Page 219 15.3.13 Sequence program all clear Clears all the sequence programs. Operation Stop the FX PLC MODE (WRITE mode) Example Clears all the sequence programs. Stop the FX PLC ! Caution The program will be erased. < READ > Press "OK" to continue. MODE Cancel Set the...
  • Page 220 15.3.14 PLC diagnostics Displays the FX PLC error message, error code, and step at which the error occurred. Operation [PLC diagnostics] Select [PLC diagnostics] with PLC diagnostics screen The following describes the contents displayed on the PLC diagnostics screen and the function of on- screen key.
  • Page 221 Remark Error details For details on an FX PLC error, refer to the manual below. Programming manual for the FX CPU used (2) Key functions The table below shows the functions of the keys that are used for the operation on the PLC diagnostics screen.
  • Page 222 15.3.15 Parameter setting Sets FX PLC parameters. Parameters that can be changed and change targets (1) Parameters that can be changed The parameters that can be changed with the MELSEC-FX list editor and the target FX PLCs are as follows. : Can be set/changed : Cannot be set/changed) Target CPU...
  • Page 223 Parameter setting screen The following describes the contents displayed on the PLC diagnostics screen and the function of on- screen keys. (1) Displayed contents Item Display contents Sets the memory space (number of steps). Memory capacity If you touch the section, you can change the memory space.
  • Page 224 (2) Key functions The table below shows the functions of the keys that are used for the operation on the parameter setting screen. Function Initializes the parameters Completes the changed setting contents. Ends parameter setting. 15 - 37 15.3 FX List Editor (For GT104[ ], GT105[ ] only) 15.3.15 Parameter setting...
  • Page 225 15.3.16 Keywords Registers, deletes, releases protection for, and sets protection for the FX PLC keywords. Function usability of the MELSEC-FX list editor for keyword protection levels The functions that can be used with the MELSEC-FX list editor depend on the keyword protection level. Available, Unavailable) Keyword protection level...
  • Page 226 Operation [Keyword setup] Select [Keyword setup] with Keyword screen and protection level When [Keyword setup] is selected with the MELSEC-FX list editor, the keyword screen is displayed. Refer to the following manual for the procedure for keyword operations. Section 11.4 Keyword Remark Keywords Refer to the following manual for details of keyword.
  • Page 227 15.3.17 List monitor The status of contacts and coils in a sequence program is displayed. Operation [ List Monitor ] Select [List Monitor] with When the list monitor is started on the FX list editor screen, the step numbers displayed on the FX list editor screen is displayed on the list monitor screen.
  • Page 228 Displays and key functions The following describes the displays for the list monitor. Item Display contents The status of contacts and coils is displayed on the left of device displays. List display area The same operations as in the READ mode of the FX list editor can be executed. Keys SubSection 15.3.8 Sequence program display) Ends the list monitor.
  • Page 229 15.3.18 Action for an incorrect key input If an incorrect key is input, cancel the input contents. Operation (1) Before touching the key (before reading/writing the input contents) Before touching the key, touch the key. After touching the key (after reading/writing the input contents) Write the command again.
  • Page 230 15.4 FX3U-ENET-ADP Communication Setting Function In GX Works2, the communication set value of the FX3U-ENET-ADP stored in the CPU can be changed. This function is not available when the communication set value of the FX3U-ENET-ADP is not set in advance in the CPU. Communication setting in the CPU In GX Works2, set in advance the communication set value of the FX3U-ENET-ADP to the CPU.
  • Page 231 Communication setting items The table below shows the communication setting items and setting range. Communication setting items Setting range Remark IP address 0.0.0.1 to 223.255.255.254 If a value outside the setting range is entered, the error 192.0.0.0 to 255.255.255.252 Subnet mask pattern message "SET NUMBER IS INCORRECT."...
  • Page 232 15.4.2 Display Operation of FX3U-ENET-ADP Communication Setting Function This section describes an example of display operation using GT1020. Main Menu(For GT1020) Touch Touch [Debug]. When the communication set value of the FX3U-ENET-ADP is not stored in the CPU When reading from the Touch [OK].
  • Page 233 15.4.3 Setting operation This section describes an example of setting the IP address using GT1020. Touch the numerical part of the octet to be changed among the 1st to 4th octets. Touch the numerical part of the octet to be changed. When the ten-key pad appears, enter a numerical value in up to 3 digits, and touch the key.
  • Page 234 When the screen shown on the left appears, the changed communication set value of the FX3U- ENET-ADP is written normally to the CPU. For making valid the contents of setting, turn OFF the power of the CPU, and then turn it ON again.
  • Page 235 When the CPU stores the symbolic information When the setting such as IP address is changed using this function and then the program is read by the programming tool from the CPU that stores the symbolic information, the following warning appears. However, the changed value is read correctly.
  • Page 236 16. CLEANING OF DISPLAY SECTION (CLEAN) In utility, the screen can be set as not to be effected by touching the screen when clean with clothes. For cleaning method, refer to "Section 18.3 Cleaning Method". 16.1 Clean 16.1.1 Display operation of clean Touch [Clean] to bring up the setting window.
  • Page 237 GRAPHIC OPERATION TERMINAL GT1030-LBD MODEL Example H/W version: H IN 20.4 26.4VDC POWER 2.2W MAX Boot OS version: AD 710001 AA BootOS Version MITSUBISHI ELECTRIC CORPORATION Rating plate: HD MADE IN JAPAN 17.1 About the OS 17 - 1...
  • Page 238 Operation on the OS installation screen Turn on the power while pressing and holding the bottom right corner of the screen. Turn the GOT power on with the lower right corner touched. The OS installation screen will appear. Install the Standard monitor OS and communication driver from drawing software.
  • Page 239 17.3 Standard Monitor OS/Communication Driver Installation Using Memory Board The memory board can be used only for GT104 , GT105 . There are the following two types for the standard monitor OS, communication driver installation using memory board. (1) Installation method when the GOT is turned on For 2-point press: When the GOT is turned on, all the OS and project data stored in the memory board are transferred to the GOT.
  • Page 240 The dialog box on the left is displayed for confirmation. Touch [YES] button to start the installation, and [NO] to abord. While the installation is executed, the dialog box on the left is displayed. Installation is completed. Touch the ESC button to restart the GOT and displays the user-created to screen.
  • Page 241 18. MAINTENANCE AND INSPECTION STARTUP AND MAINTENANCE WARNING PRECAUTIONS When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction. Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
  • Page 242 18.1 Daily Inspection Daily inspection items Inspection Inspection Item Criterion Action Method Check for loose Retighten screws within the GOT mounting status Securely mounted mounting screws. specified torque range Retighten screws Loose terminal screws Not loose Retighten terminal screws with screwdriver Connection status Retighten connector fixing...
  • Page 243 18.3 Cleaning Method Use the GOT always in a clean condition. To clean the GOT, wipe the dirty part with a soft cloth using neutral detergent. For the display operation of the [Clean] screen, refer to the following. Chapter 16 CLEANING OF DISPLAY SECTION (CLEAN) Precautions for cleaning Do not use chemicals such as thinner, organic solvents and strong acids, since they may cause the protective sheet to be deformed or the dissolvable paint on the...
  • Page 244 18.4 Battery Voltage Low Detection and Battery Replacement Low battery voltage detection and replacement The battery (For GT1030, GT104 , GT105 ) is used for backing up the clock data, alarm history or recipe data. It is recommended that you replace battery periodically. Refer to the following for the replacement procedure.
  • Page 245 Handling of Batteries and Devices with Built-in Batteries in EU Member States This section describes the precautions for disposing of waste batteries in EU member states and exporting batteries and/or devices with built-in batteries to EU member states. (1) Disposal precautions In EU member states, there is a separate collection system for waste batteries.
  • Page 246 18.5 Backlight Shutoff Detection The backlight is built into GOT(For GT105 ) for the liquid crystal display. When GOT(For GT105 ) detects backlight shutoff, the POWER LED blinks green/orange alternately. The brightness of the backlight decreases with the lapse of usage period. When backlight shutoff is detected or the display becomes unclear, replace the backlight.
  • Page 247 APPENDICES Appendix 1 External Dimensions External dimensions of GT1020 113(4.44") (0.19") 80(3.14") or more (0.39") (0.39") 76(2.99") (0.29") 76(2.99") Panel thickness: 1 to 4mm (0.37") (0.39") (0.39") (0.03" to 0.15") Unit: mm(inch) Appendix 1 External Dimensions App - 1...
  • Page 248 External dimensions of GT1030 (5.7") (0.17") 80(3.14") or more (0.39") 84 (3.3") (0.39") (3.3") Panel thickness: 1 to 4mm (0.39") (0.39") (0.82") (0.03" to 0.15") Unit: mm (inch) App - 2 Appendix 1 External Dimensions...
  • Page 249 External dimensions of GT104 139(5.47") 15.5 (0.39") (0.39") (0.61") 86(3.38") #4-40UNC (Inch screw type) M2.6 (Metric screw type) 17.5 86(3.38") Panel thickness: 5mm(0.2") or less (0.39") (0.39") (0.68") 129(5.07") Memory board connected Unit: mm(inch) Appendix 1 External Dimensions App - 3...
  • Page 250 External dimensions of GT105 164(6.46") 120(4.73") (0.87") 23(0.91") #4-40UNC (Inch screw type) M2.6 (Metric screw type) 120(4.73") Panel thickness: 5mm(0.2") or less (0.87") 152(5.99") Memory board connected Unit: mm(inch) App - 4 Appendix 1 External Dimensions...
  • Page 251 External dimensions of communication cable GT10-C R4-8P 30(1.18") 40(1.57") 250(9.84") φ13(0.51") φ7(0.27") φ25 Unit: mm(inch) 33(0.98" 1.29") Model name L (mm (inch)) Remarks GT10-C10R4-8P 1,000 (39.37") GT10-C30R4-8P 3,000 (118.11") GT10-C100R4-8P 10,000 (393.7") RS-422 cable for direct connection to FXCPU (8-pin MINI-DIN) GT10-C200R4-8P 20,000 (787.4") GT10-C300R4-8P...
  • Page 252 GT10-C R4-25P 30(1.18") 53(2.08") 16(0.62") 250(9.84") (2.16") φ7(0.27") φ25 33(0.98" 1.29") Unit: mm(inch) Model name L (mm (inch)) Remarks GT10-C30R4-25P 3,000 (118.11") GT10-C100R4-25P 10,000 (393.7") RS-422 cable for direct connection to FXCPU and A/QnACPU (25-pin D-sub) GT10-C200R4-25P 20,000 (787.4") GT10-C300R4-25P 30,000 (1181.1") GT10-C30R2-6P 30(1.18")
  • Page 253 GT01-C30R4-25P 50(1.97") 30000(1181.1") 53(2.09") (0.63") (0.63") (0.28") M2.6 M2.6 Unit: mm(inch) Model name L (mm (inch)) Remarks RS-422 cable for direct connection to FXCPU and A/QnACPU GT01-C30R4-25P 3,000 (118.11") (25-pin D-sub) GT01-C R4-25P 50(1.97") 53(2.09") (0.63") (0.63") (0.28") M2.6 M2.6 Unit: mm(inch) Model name L (mm (inch))
  • Page 254 GT01-C30R2-25P 50(1.97") 30000(1181.1") 53(2.09") (0.63") (0.63") #4-40UNC M2.6 Unit: mm(inch) Model name L (mm (inch)) Remarks RS-232 cable for direct connection to FXCPU special adaptor GT01-C30R2-25P 3,000 (118.11") (25-pin D-sub) GT01-C30R2-9S 50(1.97") 30000(1181.1") 50(1.97") (0.63") (0.63") #4-40UNC #4-40UNC Unit: mm(inch) Model name L (mm (inch)) Remarks...
  • Page 255 External dimensions of RS-232/USB conversion adaptor GT10-RS2TUSB-5S 40(1.57") 200(7.87") 75(2.95") Unit : mm(inch) Weight : Approx. 40g External dimensions of GT10-LDR memory loader 70 (2.75") (0.55") 240 (9.44") Unit: mm (inch) Weight: 0.2kg Appendix 1 External Dimensions App - 9...
  • Page 256 External dimensions of memory board 35(1.38") 19(0.75") 20(0.79") Unit: mm (inch) (0.44") External dimensions of debug stand For angle of 75 153(6.05") 260(10.24") 220(8.67") Unit: mm (inch) External dimensions of serial multi-drop connection unit 2- 4.5 57(2.25") 80(3.15") 65(2.56") Unit: mm (inch) External dimensions of connector conversion adapter 36(1.42") (0.87")
  • Page 257 External dimensions of panel-mounted USB port extension 26.3 13.7 1000(39.37") (1.03") (0.53") Approx. φ4 (0.15") Unit: mm (inch) Appendix 1 External Dimensions App - 11...
  • Page 258 Appendix 2 Usage Condition of Utility Function Different functions are available on the GOT and drawing software. : Applicable : Not Applicable Drawing Setting GT104 Setting items Function GT1020 GT1030 Designer2, GT105 Designer3) Message language switching (Japanese/ Language English) Detailed settings for the channel number and communication driver of the communication Standard I/F interface...
  • Page 259 Drawing Setting GT104 Setting items Function GT1020 GT1030 Designer2, GT105 Designer3) Display the screen to clean the display Clean section It is necessary to set the security level with drawing software. Appendix 2 Usage Condition of Utility Function App - 13...
  • Page 260 Appendix 3 Transportation Precautions When transporting lithium batteries, make sure to treat them based on the transport regulations. Appendix 3.1 Relevant models The battery for the GOT1000 Series is classified as shown in the table below. Product name Model Description Handled as Battery for GOT1000 Series GT11-50BAT...
  • Page 261 Appendix 4 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000 Series) For the functions added by version upgrade of the GT Designer2, refer to the following, or contact your local distributor. GT Designer2 Version2 Screen Design Manual Appendix 4 List of Functions Added by GT Designer2 Version Upgrade App - 15 (For GOT1000 Series)
  • Page 262 INDEX Bar code............ 2-1,2-2,2-11 Panel cutting dimensions ........6-6 Battery..........4-8,4-9,8-17,18-4 Panel mounted USB port extension ....2-2,8-33 Buzzer volume ............ 12-10 Part name..............4-1 Performance specifications ........3-2 Periodic inspection ..........18-2 Power supply specifications ........3-14 Clean..............16-1 Protective cover for oil.......2-1,2-2,8-27 Cleaning of display..........
  • Page 263 WARRANTY Please confirm the following product warranty details before using this product. 1. Gratis Warranty Term and Gratis Warranty Range If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company.
  • Page 264 GOT is a registered trademark of Mitsubishi Electric Corporation. Microsoft, Windows, Windows NT, Windows Server, Windows Vista, and Windows 7 are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Adobe and Adobe Reader are registered trademarks of Adobe Systems Incorporated.
  • Page 266 GT10 User s Manual GT10-U-E MODEL MODEL 09R819 CODE JY997D24701Z HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Effective October 2022 Specifications are subject to change without notice.