*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, wireless LAN adapter (such as NZ2WL-JPA and NZ2WL-JPS), or other system
equipment corresponding to the applicable Ethernet network system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
The use of shielded twisted pair cable (STP) is recommended in environments in which the performance against noise is
required.
For the controllers that allow the connection of a wireless LAN adapter and the setting method of wireless LAN adapters, refer to
the manual of the wireless LAN adapter to be used.
*2
A straight cable is available.
When connecting the GOT and CPU directly with Ethernet cable, a cross cable is also available.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
For the system configuration of Built-in Ethernet port QCPU, refer to the following manual.
*5
Select [QnUD(P)V/QnUDEH] for [Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*6
For the system configuration of Built-in Ethernet port LCPU, refer to the following manual.
*7
Select [LCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*8
Use C or later version of GT11H-C-37P.
*9
Select [RCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*10
For the system configuration of Built-in Ethernet port RCPU, refer to the following manual.
*11
Select [FX5CPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*12
For the system configuration of MELSEC iQ-F series, refer to the following manual.
23 - 10
23. ETHERNET CONNECTION
23.2 System Configuration
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
23.3.3 Ethernet setting
MELSEC-L CPU User's Manual (Built-In Ethernet Function)
23.3.3 Ethernet setting
23.3.3 Ethernet setting
Manuals of MELSEC iQ-R Series
23.3.3 Ethernet setting
MELSEC iQ-F User's Manual