Mitsubishi Electric GT14 User Manual page 379

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

Error
Error message
code
Auto repeat error. Confirm
540
system information.
570 Recipe device points too large.
Capacity shortage of user
571
memory (RAM)
581 Abnormal Advanced recipe file
Cannot generate Advanced
582
recipe file.
Unable to save device value to
583
Advanced recipe file.
584 Advance recipe file save error
585 Advanced recipe file upload error
Specified Advanced recipe
586
number does not exist.
Specified record number does
587
not exist.
Cannot save recipe data to read
588
only record.
Recipe device save error. Recipe
589
file does not exist.
Recipe device upload error.
590
Recipe device value does not
exist.
Advanced Recipe error. Check
591
recipe data.
595 Logging file error.
Error occurred while executing the auto repeat function of the touch
switch object.
Confirm the following.
• Confirm that the other system error has not occurred during auto
repeat.
• Confirm that any error information is not stored in the system
information/GS during auto repeat.
The number of the set points of the recipe device exceeds the specified
range.
Put the number of the set points of the recipe device within the specified
range.
There is no empty area/space in D drive.
Format the D drive in the memory to secure free area.
Advanced Recipe cannot be executed for advanced recipe file with
incorrect contents. Delete the advanced recipe file from the SD card or
USB memory.
Cannot generate advanced recipe file. Confirm the following and execute
recipe processing again.
• Confirm whether the SD card or USB memory is installed.
• Confirm whether the SD card access switch of the GOT is ON.
• Confirm the available memory of the SD card or USB memory.
Unable to save device value to advanced recipe file.
• Confirm the write-protection of the SD card or USB memory.
• Confirm whether the attribute of saving file is for reading only.
An error has occurred during the advanced recipe file writing.
Do not pull out the SD card or USB memory while the Advanced Recipe
is operating.
An error has occurred during the advanced recipe file reading.
Do not pull out the SD card or USB memory while the Advanced Recipe
is operating.
The advanced recipe of non-existing number is about to be executed.
Execute advanced recipe of existing number.
The advanced record of non-existing number is about to be executed.
Execute record of existing number.
Saving recipe is about to be executed to the record of which recipe device
value cannot be edited.
Make the recipe device value of the record editable with Advanced
Recipe Setting of GT Designer3 or specify the record of which recipe
device value can be edited.
Saving recipe is about to be executed to the advanced recipe setting that
is set for not using file.
Specify the advanced recipe setting that uses file.
Loading recipe is about to be executed to the record of which recipe
device value is not set.
Specify the record of which recipe device value is set.
The advanced recipe setting is not correct.
Confirm the advanced recipe setting of the project data and download it
to the GOT again.
Logging file error.
When collecting data again, delete logging files and management files.
20.2 Error Message and System Alarm
Action
20. TROUBLESHOOTING
17
Channel No.
storage
18
19
20
21
22
23
24
20 - 19