Got Side Settings - Mitsubishi Electric GT14 User Manual

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

41.2.4 GOT side settings

Setting communication interface
(Communication settings)
Set the channel of the equipment connected to the
GOT.
2.
1.
Select [Common]
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: TOSHIBA
• Controller Type: TOSHIBA PROSEC T/V
• I/F: Interface to be used
• Driver: TOSHIBA PROSEC T/V
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
41.2.4  Communication detail settings
OK
Click the
button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
18.1.2 I/F communication setting
41 - 10
41. CONNECTION TO TOSHIBA PLC
41.2 Serial Connection
Click!
[Controller Setting] from the
Communication detail settings
Make the settings according to the usage environment.
Item
Transmission
Speed
3.
Data Bit
4.
Stop Bit
Parity
Retry
Timeout Time
Delay Time
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 9600bps)
Set this item when change the data length
used for communication with the
connected equipment.
(Default: 7bit)
Specify the stop bit length for
communications.
(Default: 2bit)
Specify whether or not to perform a parity
check, and how it is performed during
communication.
(Default: Even)
Set the number of retries to be performed
when a communication error occurs.
(Default: 0time)
Set the time period for a communication
to time out.
(Default: 3sec)
Set this item to adjust the transmission
timing of the communication request from
the GOT.
(Default: 0ms)
Range
4800bps,
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
7bit,
8bit
1bit,
2bit
None
Even
Odd
0 to 5times
3 to 30sec
0 to 300
(ms)

Advertisement

Table of Contents
loading