23.4.10 Connecting to Ethernet module
(A Series)
This section describes the settings of the GOT and
Ethernet module (A Series) in the following case of the
system configuration.
POINT
POINT
POINT
Ethernet module (A Series)
For details of the Ethernet module (A Series), refer to
the following manual.
For A Ethernet Interface Module User's Manual
System configuration
[Controller Setting] and [Ethernet] of GT Designer3
<Ethernet module> (The settings other than the
following are set to the default)
Network No.
PLC No.
IP address
Port No.
Communication format
 Switch settings of Ethernet module
 Sequence program
*1
The Ethernet module is mounted on the base unit slot 0.
The Start I/O No. of the Ethernet module is set to "0".
*2
These setting items do not exist on the PLC side. However,
the virtual values must be set on the GOT side.
 [Controller Setting] and [Ethernet] of GT
Designer3
<GOT> (The settings other than the
following are set to the default)
Network No.
: 1
PLC No.
: 1
IP address
: 192.168.0.18
Port No.
: 5001
Communication format : UDP (fixed)
*1
*2
: 1 (virtual)
: 2 (virtual)
*2
: 192.168.0.19
: 5001
: UDP(fixed)
Switch settings of Ethernet module
Set the operation mode setting switch and exchange
condition setting switch.
AJ71E71N3-T, AJ71E71N-B5,
A1SJ71E71N3-T, A1SJ71E71N-B5,
AJ71E71N-B2, AJ71E71N-T,
A1SJ71E71N-B2, A1SJ71E71N-T,
AJ71E71N-B5T, AJ71E71-S3
A1SJ71E71N-B5T, A1SJ71E71-B5-S3,
A1SJ71E71-B2-S3
*2
A
J71E71N3-T
RUN
BUF1
BUF2
RDY
BUF3
BSY
BUF4
SW.ERR.
BUF5
COM.ERR.
BUF6
CPU R/W
BUF7
BUF8
TEST
TEST ERR.
MODE
C
0:ONLINE
(1)
1:OFFLINE
2:TEST1
3:TEST2
ON
4:TEST3
SW1
SW2
SW3
SW4
(2)
SW5
SW6
SW7
SW8
10BASE-T
*2
The figure of AJ71E71N3-T and A1SJ71E71N3-T.
(1) Operation mode setting switch
Operation mode setting
Description
switch
Online
: Necessary
(2) Exchange condition setting switch
Exchange
Setting
condition
Description
switch
setting switch
Selection of line
processing at
SW1
TCP timeout
error
Data code
SW2
setting
(binary code)
SW3
SW4
(Must not to be
used)
SW5
SW6
CPU exchange
timing setting
SW7
(Enable write at
RUN time)
Initial timing
SW8
setting
: Necessary
*1
The exchange condition setting switches of A1SJ71E71-B5-
S3 and A1SJ71E71-B2-S3 are specified as the below.
23. ETHERNET CONNECTION
23.4 PLC Side Setting
*2
A
1SJ71E71N3-T
RUN
BUF1
RDY
BUF2
BSY
BUF3
SW.ERR.
BUF4
COM.ERR.
BUF5
TEST
BUF6
TEST ERR.
BUF7
CPU R/W
BUF8
MODE
C
(1)
0:ONLINE
1:OFFLINE
2:TEST1
3:TEST2
4:TEST3
SW1
SW2
SW3
(2)
SW4
SW5
SW6
SW7
SW8
ON
10BASE-T
A1SJ71E71N3-T
Setting necessity at
Set value
GOT connection
0
(fixed)
: As necessary
: Not necessary
*1
Set
Setting necessity at
value
GOT connection
OFF
OFF
(fixed)
OFF
(fixed)
ON
(fixed)
OFF
: As necessary
: Not necessary
23 - 39