6.6 Connector Conversion Box

The Connector Conversion Box is used to connect with the external connection devices such as PLC.
6.6.1
Applicable Connector Conversion Box
The following Connector Conversion Box is applicable for the GT14 Handy.
Product name
Model
GT16H-CNB-42S
Connector
GT16H-CNB-37S
Conversion Box
GT11H-CNB-37S
6.6.2
Connector Conversion Box (GT16H-CNB-42S)
Specifications
(1) General specifications
Other specifications are the same as Handy GOT.
Item
Operating ambient temperature
Storage ambient temperature
Vibration resistance
(2) Power supply specifications
Other specifications are the same as Handy GOT.
Item
Input power supply voltage
Power consumption
Connector Conversion Box only
Inrush current
Permissible instantaneous power failure time
(3) Internal relay contact specifications
Item
Operation switch
10mA/24VDC
SW1 to SW6
(resistance load only)
1A/24VDC
Emergency stop
(resistance load)
switch
0.3A/24VDC
ES1A to ES3A
(induction load)
1A/24VDC
Grip switch
(resistance load)
DSW1, DSW2
0.3A/24VDC
(induction load)
1A/24VDC
Keylock switch
(resistance load)
(2-position switch)
0.3A/24VDC
KSWC, KSW1, KSW2
(induction load)
*1
The system may not match the safety standards. Before using the system, please check the safety standards which are required.
Packing for panel installation × 1 (accessory), Flange for GT10-9PT5S × 1 (accessory)
Screws for flange installation (M3 × 8) × 2 (accessory)
Mounting fixture for panel installation × 1 (accessory)
Screws for mounting fixtures for panel installation (M3 × 8) × 3 (accessory)
Mounting fixture for panel installation × 1 (accessory)
Screws for mounting fixtures for panel installation (M3 × 8) × 3 (accessory)
0 to 55
-20 to 70
Frequency
When installing
5 to 8.4Hz
DIN rail
8.4 to 150Hz
DC24V (+10% -15%)
10.6W or less (440mA/24VDC) (When including the consumption current of GT1455HS-QTBDE)
9.6W or less (400mA/24VDC) (When including the consumption current of GT1450HS-QMBDE)
2.2W (90mA/24VDC) (When excluding the consumption current of Handy GOT)
25A or less (at max. load) 2ms
Within 5ms
Contact rating
Each contact coordinates the operation switch status of Pressed (close)/Not pressed (open).
When the external cable is not connected, contacts are always open regardless of the switch status.
Each contact coordinates the emergency stop switch status of Pushed (open)/Return (close).
When the external cable is not connected, contacts are always open regardless of the emergency
stop switch status.
Causing a short circuit of the ES  B terminal which is close to the ES  A terminal by a short pin
(prepared by user) enables to set each contact in the close status even if the external cable is not
*1
connected.
9.4.5 Emergency stop switch wiring
When using the short-circuited ES  B terminal which is close to the ES  A terminal
• Contacts are normally operated in the close status. When pushing the emergency stop switch,
the contacts become open.
• In the following situations, contacts are closed regardless of the status of the emergency stop
switch and the external cable.
- When GT16H-CNB-42S is turned OFF
- When GT16H-CNB-42S is not supplied with the power supply (DC24V).
Each contact coordinates the grip switch status of Pressed (close)/Not pressed (open).
When the external cable is not connected, contacts are always open regardless of the grip switch
status.
Each contact coordinates the position of the keylock switch.
• When the key is on the left: KSW1 and KSWC are short-circuited.
• When the key is on the right: KSW2 and KSWC are short-circuited.
When the external cable is not connected, contacts are always open regardless of the keylock switch.
Contents
Specifications
Acceleration
Half-amplitude
-
1.75mm
2
-
4.9m/s
Specifications
Specifications
6. OPTION
6.6 Connector Conversion Box
1
2
3
4
Sweep Count
10 times each in X,
Y and Z directions
5
6
7
8
6 - 9

Advertisement