(2) Ethernet (MELSEC), Q17nNC, CRnD-700
Item
Description
Set the network No. of the GOT.
GOT NET No.
(Default: 1)
Set the station No. of the GOT.
*2
GOT PLC No.
(Default: 1)
GOT
Set the IP address of the GOT.
*1
(Default: 192.168.3.18)
IP Address
Set the subnet mask for the sub
network. (Only for connection via
router)
*1
Subnet Mask
If the sub network is not used, the
default value is set.
(Default: 255.255.255.0)
Set the router address of the default
gateway where the GOT is
Default
connected. (Only for connection via
*1
Gateway
router)
(Default: 0.0.0.0)
Ethernet
Set the GOT port No. for Ethernet
Download Port
download.
*1
(Default: 5014)
No.
GOT
Set the GOT port No. for the
Communication
connection with the Ethernet module.
Port No.
(Default: 5001)
Set the number of retries to be
performed when a communication
timeout occurs.
Retry
When receiving no response after
retries, the communication times out.
(Default: 3times)
Specify the time period from the GOT
startup until GOT starts the
Startup Time
communication with the PLC CPU.
(Default: 3sec)
Set the time period for a
Timeout Time
communication to time out.
(Default: 3sec)
Set the delay time for reducing the
Delay Time
load of the network/destination PLC.
(Default: 0ms)
*1
Click the
IP Address Setting] screen.
*2
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.

28.4.3 Ethernet setting

28 - 6
28. CNC CONNECTION
28.4 GOT Side Settings
Range
1 to 239
1 to 64
0.0.0.0 to
255.255.255.255
0.0.0.0 to
255.255.255.255
0.0.0.0 to
255.255.255.255
1024 to 5010,
5014 to 65534
(Except for 5011,
5012, 5013, and
49153)
1024 to 5010,
5014 to 65534
(Except for 5011,
5012, 5013, and
49153)
0 to 5times
3 to 255 sec
3 to 90sec
0 to 10000
(
10ms)
button and perform the setting in the [GOT
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
28.4.3 Ethernet setting
Item
Description
The host is displayed. (The host
Host
is indicated with an asterisk (*).)
Set the network No. of the
N/W No.
connected Ethernet module.
(Default: blank)
Set the station No. of the
*2
connected Ethernet module.
PLC No.
(Default: blank)
Set the type of the connected
Type
Ethernet module.
(Default: QJ71E71)
Set the IP address of the
IP Address
connected Ethernet module.
(Default: blank)
Set the port No. of the
Port No.
connected Ethernet module.
(Default: 5001)
Communication
UDP (fixed)
*1
For operating CNC monitor function, set N/W No. to "239".
*2
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
28.4.2 Communication detail settings
Range
-
Network No. of
*1
CNC
Station No. of CNC
AJ71QE71
IP address of CNC
5001
UDP (fixed)