Connecting To Freqrol-D700/F700Pj Series - Mitsubishi Electric GT14 User Manual

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

25.5.7 Connecting to FREQROL-
D700/F700PJ series
Communication settings
Make the communication settings of the inverter.
Be sure to perform the inverter reset after updating
each parameter.
(1) Communication port and corresponding parameters
GOT connection
Parameters corresponding to inverter
destination
PU connector
Pr.79, Pr.117 to Pr.124, Pr.340, Pr.342, Pr.549
(2) Communication settings of inverter
Set the following parameters using the PU (parameter
unit). Set Pr.160 (User group read selection) to 0 "The
simple mode and extended parameters can be
displayed" before making the parameter settings.
Do not change these parameters, even though they
can be monitored from the GOT. If they are changed,
communication with the GOT is disabled
*1
Parameter No.
Setting item
PU communication station
Pr.117
number
*2
Pr.118
PU communication speed
PU communication stop bit
Pr.119
length*2
PU communication parity
Pr.120
*2
check
Number of PU
Pr.121
communication retries
PU communication check
Pr.122
time interval
PU communication wait time
Pr.123
setting
PU communication CR/LF
Pr.124
selection
Protocol selection
Pr.549
Operation mode selection
Communication startup
Pr.340
mode selection
Communication EEPROM
Pr.342
write selection
*1
Setting items are parameter names described in the manual
of FREQROL-D700 series.
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change
the parameters on the inverter to correspond with the GOT
settings.
*3
Inverter default values (No need to change)
25 - 38
25. INVERTER CONNECTION
25.5 FREQROL Series Inverter Side Settings
Set
Settings
value
0 to 31
25.5.13 Station number
setting
*3
19200bps
192
Data length: 7bit
10
Stop bit length: 1bit
1
Odd
The inverter will not
9999
come to an alarm stop.
Communication check
9999
suspension
0
0ms
*3
With CR, without LF
1
Mitsubishi inverter
*3
0
protocol
External operation mode
*3
Pr.79
0
at power on
1
Network operation mode
Written to RAM and
*3
0
EEPROM
HINT
HINT
HINT
Automatic setting with Pr.999 (FREQROL-F700PJ
series only)
If Pr.999 is set as the following, the communication
settings other than [PU communication station
number]
and
[Communication
selection] can be automatically set in a batch to the
default communication settings of the GOT side.
Parameter
Set
Description
No.
value
GOT initial
*1
10
settings
Pr.999
(PU connector)
*1
When the value of Pr.999 is monitored, 9999 is always
monitored.
EEPROM
write
Operation in parameter setting
mode
[AUTO]
[GOT]
[1]
Write