31.6.8

Accessing by MT Works2

This section explains the procedure to set the FA
transparent function of MT Works2 with an example of
connecting to motion controller CPU (Q series).
When connecting the GOT and personal
computer with USB
(1) Connecting the GOT and PLC in direct CPU
connection
1.
Click [Transfer setup]
2.
The [Transfer Setup] is displayed.
3.
Set the [Transfer Setup]:
PC side I/F: Serial USB
PLC side I/F: GOT
Other station: No specification
4.
Double-click [Serial] of the PC side I/F to display [PC
side I/F Serial setting].
31 - 40
31. FA TRANSPARENT FUNCTION
31.6 Personal Computer Side Setting
[Online].
5.
Check the following for [PC side I/F Serial Setting].
When connecting the GOT and PC with USB
Mark the [USB] checkbox.
6.
Double-click [GOT] of the CPU side I/F to display
[CPU side I/F Detailed Setting of GOT].
7.
Check-mark the following in [CPU side I/F Detailed
Setting of GOT].
Direct CPU connection
Mark the [via GOT (direct coupled) transparent mode]
checkbox.
Ethernet connection
Mark the [via GOT (Ethernet) transparent mode]
checkbox and click [Set].
[GOT (Ethernet) transparent setting] is displayed. Set
it according to the system configuration.
8.
The screen returns to [Transfer setup]. Click
to check if GX Developer has been
connected to the motion controller (Q mode).

Advertisement

Table of Contents
loading

Table of Contents