31.6.14 Accessing by RT ToolBox2

This section explains the procedure to set the FA
transparent function of RT ToolBox2 with an example of
connecting to CRnQ-700.
Connecting the GOT and controller in direct
CPU connection (CRnQ-700 only)
1.
Right-click a project name to be a target on the
project tree of RT ToolBox2.
Click [Edit Project].
2.
Set [Method] to [CRnQ].
3.
Click [Detail].
4.
Check-mark the following in [Serial port].
When connecting the GOT and PC with USB
Mark the [USB] checkbox.
5.
Click [Detail].
6.
Check-mark the following in [PLC side I/F Detailed
setting of PLC module].
Direct CPU connection
[via GOT (direct coupled) transparent mode]
7.
As necessary, select a CPU that is targeted in [CPU].
31. FA TRANSPARENT FUNCTION
31.6 Personal Computer Side Setting
25
26
27
28
29
30
31
31 - 43