6.
Double-click [GOT] of the PLC side I/F to display
[PLC side I/F Detailed Setting of GOT].
7.
Check-mark the following in [PLC side I/F Detailed
Setting of GOT].
Direct CPU connection
Mark the [via GOT (direct coupled) transparent mode]
checkbox.
8.
The screen returns to [Transfer Setup]. Click
to check if GX Developer has been
connected to the QCPU (Q mode).
31 - 30
31. FA TRANSPARENT FUNCTION
31.6 Personal Computer Side Setting
(b) Connecting to FXCPU
1.
Click the Connection Destination view
Destination]
[(Connection target data name)] in the
Navigation window of GX Works2.
2.
The [Transfer Setup] is displayed.
3.
Set the [Transfer Setup]:
PC side I/F: Serial USB
PLC side I/F: GOT
Other station: No specification
4.
Double-click [Serial USB] of the PC side I/F to display
[PC side I/F Serial Setting].
5.
Check-mark either of the following in [PC side I/F
Serial Setting].
When connecting the GOT and PC with serial
Mark the [RS-232C] checkbox.
When connecting the GOT and PC with USB
Mark the [USB] checkbox.