HOW TO READ THIS MANUAL

Symbols
Following symbols are used in this manual.
PLC
RS-422 connector
Communic
Model name
conversion Cable
ation type
-
RS-232
MELSEC-Q
FA-CNV2402CBL(0.2m)
RS-422
FA-CNV2405CBL(0.5m)
5.3 GOT Side Settings
5.3.1
Setting communicationinterface
(Communication settings)
Set the channel of the connected equipment.
2.
1.
Select [Common] → [Controller Setting] from the menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: Mitsubishi
• Controller Type: Set the option according to the
Controller Type to be connected.
• I/F: Interface to be used
• Driver: Set either of the following option according
to the Controller Type to be connected.
• BUS (Q)
• BUS (A/QnA)
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage environment.
5.3.2 Communication detail settings
Click the
OK
button when settings are completed.
Since the above page was created for explanation purpose, it differs from the actual page.
Connection cable
Connector
External cable
conversion box
Cable model
GT11-C30R2-6P(3m)
GT11H-C30-37P(3m)
GT11H-CNB-37S
GT11H-C60-37P(6m)
GT01-C30R4-25P(3m)
GT11H-C100-37P(10m)
GT01-C100R4-25P(10m)
5.3.2
Communication detail settings
(1) Bus (Q)
Item
3.
Number of stages
(Default: 1)
Slot No.
(Default: 0)
Monitor speed
(Default: Normal)
4.
(2) Bus (A/QnA)
Click!
Item
Number of stages
(Default: 1)
Slot No.
(Default: 0)
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be changed
on the Utility's [Communication Settings] after writing
[Communication Settings] of project data.
For details on the Utility, refer to the following manual.
GT User's Manual
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
(3) When changing Stage No. and Slot No.
Change these settings with the PLC CPU turned
OFF, and then reapply the power to the PLC CPU
and GOT.
Failure to do so may generate a system alarm
(No.487).
Following GOT is shown.
Number of
GOT
Total
connectable
model
distance
Model name
equipment
6m
1 GOT for 1
computer
link module
13m
1. 2. 3.
Indicates the operation steps.
[ ] : Indicates the setting items displayed on
Description
Range
1 to 7
0 to 9
High/Normal/Low
HINT
HINT
HINT
Description
Range
1 to 7
0 to 7
Indicates the location of related content.
Shows GT14 Handy.
...
the software and GOT screen.
POINT
POINT
POINT
Refers to the information required.
Refers to information useful
for operation.
A - 39