12.2 Operation Setting (Settings Regarding Operation)

12.2.1 Operation setting functions
Setting regarding GOT operation can be set.
The items which can be set are described below. Touching the each item part makes the respective setting become
possible.
Function
Buzzer volume setting
Window move buzzer volume setting
Security setting screen change
Utility call key screen change
Key sensitivity setting
Touch panel calibration
USB mouse/keyboard setting
®
VNC
server function setting
*1
Relation between the [Key sensitivity] setting and [Key reaction speed]
The larger the set value in [Key sensitivity] is, the shorter the time taken from touching the touch panel until the GOT responds
becomes.
E.g. decrease the value set for [Key sensitivity] when double-touch is made when touching the GOT screen only once. (Decrease
the reaction speed.)
The relation between the [Key sensitivity] setting and [Key reaction speed] is as follows.
[Key sensitivity] setting
[Key reaction speed]
POINT
POINT
POINT
Operation setting by GT Designer3
Select [Common Settings]
of buzzer sound and buzzer sound at window move.
To change a part of the setting after downloading the project data, change the setting at the display setting of GOT.
GT Designer3 Version1 Screen Design Manual (Fundamentals)
Description
Buzzer volume setting can be changed.
Whether turn ON/OFF buzzer when move window can be selected.
Security level change screen can be displayed.
12.2.4 Security level change
Utility call key setting screen can be displayed.
12.2.5 Utility Call Key Setting
The sensitivity of touch panel when GOT screen is touched can be set.
E.g. a setting can be changed when double-touch is made when
touching the GOT screen only once. (For preventing chattering)
Touch panel reading error can be corrected.
12.2.6 Adjusting the touch panel position (Touch panel calibration)
Set the setting items related with USB mouse/keyboard.
12.2.7 USB mouse/keyboard setting
The authorization guarantee time for the VNC
set.
Quick response
8
7
6
0ms
-20ms
-10ms
(Standard)
[GOT Environment Settings]
12. DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.2 Operation Setting (Settings Regarding Operation)
OFF/SHORT/LONG
(At factory shipment: SHORT)
ON/OFF
(At factory shipment: ON)
1 to 8
®
0 to 3600 seconds
server function can be
<At factory shipment: 0 seconds>
5
4
3
+10ms
+20ms
+40ms
[GOT Setup] from GT Designer3 to make the settings
10
Setting range
11
-
-
*1
12
-
-
13
Slow response
2
1
14
+80ms
+120ms
15
16
12 - 7