32.5 Robot Controller Side Setting

POINT
POINT
POINT
IAI Robot Controller
For details of IAI Robot Controller, refer to the following
manual.
IAI Robot Controller user's Manual
32.5.1
Connecting to X-SEL
Parameter setting
Enter the following parameters using peripheral
software. When setting parameters, set the mode
switch of the controller to "MANU".
Parameter
Parameter name
Usage of SIO channel 1
I/O parameter 90
opened to user
Station code of SIO channel
I/O parameter 91
*1
1
opened to user
Baud rate type of SIO
*2
I/O parameter 92
*1
channel 1
opened to user
Data length of SIO channel
I/O parameter 93
*1
1
opened to user
Stop bit length of SIO
I/O parameter 94
*1
channel 1
opened to user
Parity type of SIO channel
I/O parameter 95
*1
1
opened to user
IAI-protocol minimum
response delay for SIO
*3
I/O parameter 97
*1
channel 1
opened to user
Other parameter 46
Other setting bit pattern
*1
For X-SEL(P/Q/PX/QX), the parameter becomes the SIO
channel 0 opened to user.
*2
Indicates only the transmission speeds that can be set on
the GOT side.
Specify the transmission speed to match the transmission
speed of the GOT.
*3
Set it only when a wait time is required before the response
and transmission to the GOT request. Normally, the
communication is available using default values.
*4
When using the "MANU" mode, the set value is fixed to the
value with *. Adjust the settings of the GOT side to the *
settings.
However, the communication setting of the PC software
becomes the setting of X-SEL after the PC software for X-
SEL is connected. In this case, adjust the communication
setting of the GOT to the setting of the PC software.
*4
Set value
• When used in
"MANU"
Set either of the
following.
0: SEL opened
*1
program
2: IAI protocol B
• When used in
"AUTO"
2: IAI protocol B
0 to 255
153*
0: 9600bps*
1: 19200bps
2: 38400bps
3: 57600bps
5: 115200bps
7bit, 8bit*
1bit*, 2bit
0: None*
1: Odd
2: Even
0 to 999(ms)
bit0 to 3 = 1
(fixed)
32. CONNECTION TO IAI ROBOT CONTROLLER
Mode switch
(1) X-SEL K type
(a) When setting the mode switch to "MANU"
Connect the GOT to the following teaching
connector.
(b) When setting the mode switch to "AUTO"
Connect the GOT to the following general RS232C
port connector.
*1
The teaching connector and general RS232C port connector
cannot be used at the same time.
(2) Other than X-SEL K type
Set the mode switch to "MANU" or "AUTO" and connect
the GOT to the following teaching connector.
32.5 Robot Controller Side Setting
32
33
Mode switch
34
Teaching
*1
connector
General
RS232C
port
connector
*1
35
36
Mode switch
Teaching
37
connector
38
39
32 - 25