25.5 FREQROL Series Inverter Side Settings

For details of the inverter, refer to the manual of each
series.
25.5.1 Connecting to FREQROL-
S500, S500E, or F500J series
Communication settings
Make the communication settings of the inverter.
Be sure to perform the inverter reset after updating
each parameter.
(1) Communication port and corresponding parameters
GOT connection
Parameters corresponding to inverter
destination
RS-485 port
Pr.79, n1 to n7, n10 to n12
(2) Communication settings of inverter
Set the following parameters using the PU (parameter
unit). Set Pr.30 (Extended function selection) to 1 [With
display] before making the parameter settings.
Do not change these parameters, even though they
can be monitored from the GOT. If they are changed,
communication with the GOT is disabled
*1
Setting item
Parameter No.
Communication station
n1 (331)
number
*2
n2 (332)
Communication speed
*2
n3 (333)
Stop bit length
Parity check presence/
n4 (334)
*2
absence
Number of communication
n5 (335)
retries
Communication check time
n6 (336)
interval
Wait time setting
n7 (337)
CR/LF selection
n11 (341)
*5
-
Protocol selection
Operation mode selection
Pr.79
Link start mode selection
n10 (340)
2
n12 (342)
E
PROM write selection
*1
Setting items are parameter names described in the manual
of FREQROL-S500, S500E, and F500J series.
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change
the parameters on the inverter to correspond with the GOT
settings.
*3
Inverter default values (No need to change)
*4
When being monitored from the GOT, the parameter n1
through n7 correspond with Pr.331 through Pr.337, and the
parameter n10 through n12 correspond with Pr.340 through
Pr.342.
Numbers in brackets show the parameter number when the
parameter unit is in use.
*5
There is no setting for this item on the inverter side.
Set
*4
Settings
value
0 to 31
25.5.13 Station
number setting
*3
19200bps
192
Data length: 7bit
10
Stop bit length: 1bit
1
Odd
The inverter will not
---
come to an alarm
(65535)
stop.
Communication check
---
suspension
0
0ms
With CR
*3
1
Without LF
-
-
External operation
*3
0
mode at power on
Computer link
1
operation
Written to RAM and
*3
0
EEPROM
25.5.2 Connecting to FREQROL-
E500 series
Communication settings
Make the communication settings of the inverter.
Be sure to perform the inverter reset after updating
each parameter.
(1) Communication port and corresponding parameters
GOT connection
Parameters corresponding to inverter
destination
PU connector
Pr.79, Pr.117 to Pr.124, Pr.146, Pr.342
(2) Communication settings of inverter
Set the following parameters using the PU (parameter
unit).
Do not change these parameters, even though they
can be monitored from the GOT. If they are changed,
communication with the GOT is disabled
*1
Parameter No.
Setting item
Communication station
number
*2
Communication speed
*2
Stop bit length
Parity check presence/
*2
absence
Number of communication
retries
Communication check time
interval
Wait time setting
CR/LF presence/absence
selection
*4
Protocol selection
Operation mode selection
Communication startup
*4
mode selection
2
E
PROM write selection
Frequency setting command
*5
selection
*1
Setting items are parameter names described in the manual
of FREQROL-E500 series.
*2
Settings on the GOT can be changed.
When changing the settings on the GOT, be sure to change
the parameters on the inverter to correspond with the GOT
settings.
*3
Inverter default values (No need to change)
*4
There is no setting for this item on the inverter side.
*5
The setting is required for Frequency setting command
selection.
25. INVERTER CONNECTION
25.5 FREQROL Series Inverter Side Settings
Set
Settings
value
Pr.117
0 to 31
25.5.13 Station number
setting
*3
Pr.118
19200bps
192
Data length: 7bit
Pr.119
10
Stop bit length: 1bit
Pr.120
1
Odd
9999
The inverter will not
Pr.121
(65535)
come to an alarm stop.
Communication check
Pr.122
9999
suspension
Pr.123
0
0ms
With CR
*3
Pr.124
1
Without LF
-
-
-
*3
Pr.79
PU operation mode
1
-
-
-
Written to RAM and
*3
Pr.342
0
EEPROM
Built-in frequency
Pr.146
9999
setting potentiometer
invalid
25 - 35
25
26
27
28
29
30
31