Installation
The connector conversion box can be installed on the panel face directly or installed with the mounting fixtures.
(1) Direct installation on the panel face
Drill a mounting slot of the following size on the panel face.
18 (0.7")
Panel cut area
Unit: mm (inch)
(2) Installing on the panel face
Fit the connector conversion box from the back side of the panel face, and fix it with four M3 screws (prepared
by user).
In the connector conversion box, thread of M3, 6mm in depth is cut in each mounting hole.
Prepare four M3 mounting screws separately while considering the thickness of the panel face.
Tighten the mounting screws within the specified torque range.
Tightening torque
Make sure that interfering objects are not located within 50mm from the rear face so that the connector of a PLC
cable is not hindered. To wire the terminal block, keep a space of 25mm or more on both sides of the connector
conversion box.
M3 screw × 4
(prepared by user)
6 - 30
6. OPTION
6.6 Connector Conversion Box
28 (1.1")
18 (0.7")
Drill 4-3.5
0.49 to 0.68N•m
Panel face
25
Screw depth
(0.99")
of 6 mm
25
(0.99")
Unit: mm (inch)