23.4.1 Connecting to Built-in Ethernet
port CPU (one-to one
connection)
This section describes the settings of the GOT and Built-in
Ethernet port CPU in the following case of system
configuration.
POINT
POINT
POINT
Built-in Ethernet port CPU
For details of Built-in Ethernet port CPU, refer to the
following manual.
Manuals of MELSEC iQ-R Series
Manuals of MELSEC iQ-F Series
System configuration
For connecting one Built-in Ethernet port CPU to one
GOT, the PLC side settings are not required. Set
[Ethernet] for [Controller Setting] on GT Designer3, and
then connect Built-in Ethernet port CPU to the GOT.
(For MELSEC iQ-R Series)
[Controller Setting] and [Ethernet] of GT Designer3
<Connecting to Built-in Ethernet port CPU>
(The following settings are set to the default)
Network No.
PLC No.
IP address
Port No.
Communication
format
*1
For the settings when using system devices including a hub
and a transceiver, refer to the following.
23.4.6 Connecting to Built-in Ethernet port CPU
(multiple connection)
*2
These setting items do not exist at the PLC side. However,
the virtual values must be set on the GOT side.
 [Controller Setting] and [Ethernet] of GT
Designer3
23 - 18
23. ETHERNET CONNECTION
23.4 PLC Side Setting
<GOT>
(The settings other than the
following are set to the default)
Network No.
: 1
PLC No.
: 1
IP address
: 192.168.3.1
Port No.
: 5001
Communication
: UDP (fixed)
format
*1
*2
: 1 (virtual)
*2
: 2 (virtual)
: 192.168.3.39
: 5006 (fixed)
: UDP (fixed)
[Controller Setting] and [Ethernet] of GT
Designer3
POINT
POINT
POINT
(1) [Controller Setting] and [Ethernet] of GT
Designer3
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
23.3.1 Setting communication interface
(Communication settings)
(2) Ethernet setting
When connecting Built-in Ethernet port RCPU to a
GOT, the setting items for the network No. and
station No. do not exist at the PLC side. However,
these virtual values must be set on the GOT side.
Therefore, set the network No. and station No.
Set the network No. that does not exist on the
network system and any station No.
(1) Controller setting
Item
GOT NET No.
GOT PLC No.
GOT IP Address
GOT Port No.
(Communication)
GOT Port No.
(Ethernet Download)
Default Gateway
Subnet Mask
Retry
Startup Time
Timeout Time
Delay Time
(2) Ethernet setting
Item
Host
N/W No.
PLC No.
Ethernet
Type
setting No.1
IP address
Port No.
Communication
*1
Set the same value as that of GOT N/W No.
*2
Set a value different from that of GOT PLC No.
*3
In the case of MELSEC iQ-F series, it is FX5CPU.
*4
In the case of MELSEC iQ-F series, it is 5562 (fixed).
*5
In the case of MELSEC iQ-F series, it is TCP (fixed).
Set value (Use default value)
1
1
192.168.3.1
5001
5014
0.0.0.0
255.255.255.0
3times
3sec
3sec
0ms
Set value
*
*1
1
*2
2
*3
RCPU
192.168.3.39
*4
5006 (fixed)
*5
UDP (fixed)