25.6 Device Range that Can Be Set

For details on the device range of controllers that can be used on GT14 Handy, refer to the following manuals.
25.7 Precautions
Station No. of inverter system
Make sure to establish inverter system with No.0 station.
Number of inverters
Up to 10 inverters can be connected.
Parameter setting
(1) Communication parameter change
Do not make any change for each communication parameter of the inverter side from GOT.
If changed, communication with the inverter will no longer be possible.
(2) When setting "8888" or "9999" to inverter parameter (Pr)
"8888" and "9999" designate special functions. When specifying the values from the GOT1000, it will be as
follows.
Set value of inverter side
Screen switching devices, and system information devices
Make sure to use GD for screen switching devices and system information devices when the GOT is connected to
only the inverter.
GOT clock control
Since the inverter does not have a clock function, the settings of [time adjusting] or [time broad cast] by GOT clock
control will be disabled.
25 - 44
25. INVERTER CONNECTION
25.6 Device Range that Can Be Set
GT Designer3 Version1 Screen Design Manual (Fundamentals)
GOT1000 Series Connection Manual (Mitsubishi Products) for GT Works3
Value specified by GOT
8888
9999
65520
65535