Ethernet setting
Item
Description
The host is displayed. (The host is
Host
indicated with an asterisk (*).)
Set the network No. of the connected
N/W No.
Ethernet module.
(Default: blank)
Set the station No. of the connected
*1
Ethernet module.
PLC No.
(Default: blank)
Controller Type TOSHIBA (fixed)
Set the IP address of the connected
IP Address
Ethernet module.
(Default: blank)
Set the port No. of the connected
Port No.
Ethernet module.
(Default: 9600)
Communication UDP (fixed)
*1
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
41.3.2  Communication detail settings
POINT
POINT
POINT
(1) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
41 - 14
41. CONNECTION TO TOSHIBA PLC
41.3 Ethernet Connection

41.3.3 PLC side setting

Setting of operation mode switch and station
address switch
Set value
-
1 to 127
1 to 254
TOSHIBA (fixed)
PLC side IP
address
256 to 65534
(1) Station number switch
The station address setting switches are hexadecimal
UDP (fixed)
rotary switches that determine the station address on
the Ethernet network.
Set the station address (1 to 254) that has been
assigned upon system configuration in a HEX code.
Assign an address with a different value to each of the
nodes in the system.
Set as follows.
Switch name
STN-H
STN-L
(2) Operation mode setting switch
Setting item
Operation
mode
IP address
type
Station address
setting switch
Operation mode
setting switch
Settings
Upper address: 0 to F (Hex)
Lower address: 0 to F (Hex)
Set value
1
Nomal use
OFF OFF
ON
Cannot be used
OFF
Class B
*1
172.16.64.XX
Reserved
Class C
*2
192.168.0.XX
*3
Tool setting
*1
XX indicates the value of the station address setting switch.
Subnet mask: 255.255.192.0
*2
XX indicates the value of the station address setting switch.
Subnet mask: 255.255.255.0
*3
It can be set freely from the engineering tool for the Unified
Controller nv Series, and the value has precedence over the
value of the station address setting switches.
Setting range
01 to FE (Hex)
Switch No.
2
3
6
7
8
OFF
OFF
OFF
ON
OFF
OFF OFF
OFF
OFF
ON
OFF
OFF OFF
ON
ON
ON
ON