Mitsubishi Electric GT14 User Manual page 683

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

4.
Double-click [GOT] of the CPU side I/F to display
[CPU side I/F Detailed Setting of GOT].
5.
On the [PLC side I/F Detailed Setting of GOT], mark
the [via GOT(Ethernet) transparent mode] checkbox.
6.
By clicking [Set], the [GOT (Ethernet) transparent
setting] is displayed.
Here, set the C Controller module (Q Series)
(Q24DHCCPU-V), which is firstly connected via a
GOT.
7.
Specify the IP address assigned to the C Controller
module (Q Series) (Q24DHCCPU-V) for [IP Address].
8.
The screen returns to [Transfer Setup]. Click
to check if Setting/Monitoring tool for C
Controller module has been connected to the C
Controller module (Q Series) (Q24DHCCPU-V).
31. FA TRANSPARENT FUNCTION
31.6 Personal Computer Side Setting