36.5.6 Connecting to U-01DM

Setting switches
Make the communication settings using each setting switch.
Front
Address selection switch
Communication and the
DIP switch for a setup of
a protocol
(1) Address selection switch (SW2, SW3)
Switch No.
Setting
SW2
Code higher rank (10
SW3
Code low rank (10
(2) Communication and the DIP switch for a setup of a
protocol (SW4)
Setting item Set value
1
9600bps
OFF
ON
Transmission
19200bps
ON
ON
*1
speed
38400bps
OFF
OFF
ODD
Parity
NONE
Self-
OFF
diagnostic
Response
0ms
delay time
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Specify the transmission speed to match the transmission
speed of the GOT.
36 - 32
36. CONNECTION TO KOYO EI PLC
36.5 PLC Side Setting
Back
Contents of setting
1
figures)
01 to 5A
0
figures)
Switch No.
2
3
4
5
6
7
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
(3) Communication and the DIP switch for a setup of a
protocol (SW5)
Item
Peer to Peer
M/S
TOUT existence
ASCII/HEX
8
OFF
Switch No.
Set value
1
2
OFF
OFF
Slave
OFF
Enable
HEX
3
4
OFF
OFF