Mitsubishi Electric GT14 User Manual page 906

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

RS422 connection diagram 6)
* 1
PLC side
L1S+
L1S-
L1R+
L1R-
0V
FG
* 2
*1
Terminating resistors should not be provided for a PLC and
an RS-232/RS-422 interface converter which will be
terminals.
*2
Connect FG grounding to the appropriate part of a cable shield
line.
RS422 connection diagram 7)
Connector conversion
box
side
RDA
2
RDB
7
SDA
1
SDB
6
SG
5
RSA
3
* 2
CSA
4
RSB
8
CSB
9
FG
-
*1
Terminating resistors should not be provided for a PLC and
an RS-232/RS-422 interface converter which will be
terminals.
*2
Connect FG grounding to the appropriate part of a cable shield
line.
RS422 connection diagram 8)
External cable
GT11H-C-37P side
FG(Shield)
1
SDA
2
SDB
3
RSA
4
RSB
5
RDA
6
RDB
7
CSA
8
CSB
9
SG
10
* 2
*1
Terminating resistor should be provided for a PLC which will
be a terminal.
*2
Connect FG grounding to the appropriate part of a cable shield
line.
37 - 16
37. CONNECTION TO JTEKT PLC
37.3 Connection Diagram
* 1
PLC side
PLC side
L1S+
L1S+
L1S-
L1S-
L1R+
L1R+
L1R-
L1R-
0V
0V
FG
FG
* 2
PLC
Link unit
* 1
* 1
side
side
L1S+
S+
L1S-
S-
L1R+
R+
L1R-
R-
0V
0V
FG
FG
PLC
Link unit
* 1
* 1
side
side
L1R+
R+
L1R-
R-
L1S+
S+
L1S-
S-
0V
0V
FG
FG
RS422 connection diagram 9)
External cable
* 1
GT11H-C side
FG(Shield)
Shield
SDA
W/R (A)
SDB
W/BK (A)
RSA
GY/R (A)
RSB
GY/BK (A)
RDA
O/R (A)
RDB
O/BK (A)
CSA
Y/R (A)
CSB
Y/BK (A)
SG
PK/R (A)
*1
Terminating resistor should be provided for a PLC which will
be a terminal.
*2
Connect FG grounding to the appropriate part of a cable shield
line.
Precautions when preparing a cable
(1) Cable length
(a) The length of the RS-422 cable used for connecting the
connected equipment to the communication converter
The length of the RS-422 cable must be 500m or
less.
(b) The length of the RS-422 cable used for connecting the
connected equipment to the GOT.
The total distance (between GOT and controllers)
of RS-422 cable must be 13m or less.
(2) Connector conversion box side connector
For the connector conversion box side connector, refer
to the following.
6.6 Connector Conversion Box
(3) External cable side connector
For the connector specifications of the external cable
side, refer to the following.
8.2 External Cable, Relay Cable
(4) JTEKT PLC side connector
Use the connector compatible with the JTEKT PLC side
module.
For details, refer to the JTEKT PLC user's manual.
PLC
Link unit
* 1
* 1
side
side
L1R+
R+
L1R-
R-
L1S+
S+
L1S-
S-
0V
0V
FG
FG
* 2