Ethernet Setting - Mitsubishi Electric GT14 User Manual

Hide thumbs Also See for GT14:
Table of Contents

Advertisement

POINT
POINT
POINT
(1) Example of [Detail setting].
For examples of [Detail Setting], refer to the
following.
23.4 PLC Side Setting
(2) Communication interface setting by Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
11. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(3) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.

23.3.3 Ethernet setting

Item
Description
The host is displayed. (The host
Host
is indicated with an asterisk (*).)
Set the network No. of the
N/W No.
connected Ethernet module.
(Default: blank)
Set the station No. of the
*4
connected Ethernet module.
PLC No.
(Default: blank)
Set the type of the connected
*1
Ethernet module.
Type
(Default: QJ71E71)
Set the IP address of the
IP Address
connected Ethernet module.
(Default: blank)
Port No.
Communic
ation
POINT
POINT
POINT
Range
-
1 to 239
*5
1 to 120
RCPU,
RnCCPU,
FX5CPU,
QnUD(P)V/QnUDEH,
QnD(H)CCPU,
LCPU,
Q17nNC, RJ71EN71,
QJ71E71/LJ71E71,
AJ71QE71, AJ71E71
FX
0.0.0.0 to
255.255.255.255
Item
Description
Set the port No. of the connected
*2
Ethernet module.
(Default: 5001)
UDP
*3
*1
Select one of the following [Controller Type].
• Built-in Ethernet port (hereafter CPU): RCPU
RnMTCPU, RnPCPU
• Connection to Built-in Ethernet port QCPU: QnUD(P)V/
QnUDEH
• C Controller module (Q Series): QnD(H)CCPU
• Connection to Built-in Ethernet port LCPU: LCPU
• Ethernet module (NZ2GF-ETB): QJ71E71
• Q17nNCCPU: Q17nNC
• Ethernet module (MELSEC iQ-R Series): RJ71EN71
• Ethernet module (Q, L Series): QJ71E71/LJ71E71
• Ethernet module (QnA Series): AJ71QE71
• Ethernet module (A Series): AJ71E71
• Ethernet module (FX Series): FX
• Built-in Ethernet port FXCPU: FX
For the applicable Ethernet module, refer to the following.
23.2 System Configuration
*2
Set only when selecting [AJ71E71] in [Controller Type].
When other than [AJ71E71] is selected, the port No. is as
follows.
• [RCPU], [RnCCPU], [QnUDE(H)]: 5006 (fixed)
• [FX5CPU]: 5562 (fixed)
• [RJ71EN71], [Q17nNC], [QJ71E71], [AJ71QE71]:
5001 (fixed)
• [FX]: 5551 (When using FX3U-ENET-L)
5556 (When using FX3U-ENET-ADP)
When using built-in Ethernet port FXCPU: 5556
*3
When selecting the FX in [Controller Type], the
communication type is the TCP (fixed).
*4
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
23.3.2 Communication detail settings
*5
When selecting other than RCPU and RJ71EN71, the range
is 1 to 64.
(1) Example of [Ethernet]
For examples of [Ethernet], refer to the following.
23.4 PLC Side Setting
(2) Parameter reflection function of MELSOFT
Navigator
(a) The color of the cells for the items which are
reflected to GT Designer3 from MELSOFT
Navigator changes to green. Set items, which
are displayed in green cells, from the
MELSOFT Navigator.
(b) When the settings of N/W No., PLC No., type
or IP address are reflected to the parameter
from the MELSOFT Navigator, those settings
are added. Items set in advance are not
deleted. However, if the combination of the N/
W No. and the PLC No. or the IP address
overlaps, the item set in advance is
overwritten.
23. ETHERNET CONNECTION
23.3 GOT Side Settings
17
Range
1024 to 65534
UDP,
TCP
18
19
20
21
22
23
24
23 - 15