Hitachi Compute Blade 2000 User Manual page 312

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

Properties: Controller properties submenu 1
Click Next in the Controller Properties screen, and the following screen appears:
Firmware version; 2.110.63-1184
Display item
A Battery Backup
B Coercion Mode *1
C Set Factory Defaults
*2
D S.M.A.R.T Polling *4
E Cluster Mode *3
F Alarm Control
G Rebuild Rate *3
H Patrol Read Rate *3
I
BGI Rate *3
J
Cache Flush Interval
*3
K CC Rate *3
L Spinup Drive Count *4 Number of hard disk motors started
M Reconstruction Rate
*3
N Spinup Delay *4
O NCQ *4
Display/content
Battery backup unit mount status.
Setting the capacity control for the
physical hard disk used for disk
array building
Returning all the settings to their
Defaults values
Setting the interval of S.M.A.R.T.
reporting
Setting the cluster mode
Sounding the buzzer on the
controller in the event of a fault at a
connected device
Priority of rebuilding
Priority of patrol reading
Priority of background initializing
Flash timing for write-cache data
Priority of integrity inspection
at system startup
Priority of capacity expansion
Timing for hard disk motors started
at system startup
Setting the NCQ command
261
Setting/display value **
None
[None (using the entire capacity)] /
128 MB-way (using a capacity as a
multiple of 128 MB) / 1 GB-way
(using a capacity as a multiple of 1
GB)
0 to 65535
/
300
/
[600]
[Disabled (invalid)] /
Enabled (valid)
[Disabled (not sounding)] / Enabled
(sounding) /
Silence (stop sounding
temporarily)
0 to 100
/ [30]
0 to 100
/ [30]
0 to 100
/ [30]
1 to 255
/ [4]
0 to 100
/ [30]
0 to 8
/
[1]
0 to 100
/ [30]
0 to xxx
/
[6]
[Enabled] /
Disabled

Advertisement

Table of Contents
loading

Table of Contents