(b) moduleStatusMm group (5/7)
Object
No
identifier
30
mmVoltSensor6
Value
31
mmVoltSensor6
Valid
32
mmVoltSensor7
Name
33
mmVoltSensor7
Value
34
mmVoltSensor7
Valid
35
mmVoltSensor8
Name
36
mmVoltSensor8
Value
(*1)
"unknown" is shown in the process of setting redundancy, or when no management
module is installed or the status cannot be obtained.
(*2)
"unknown" is shown when no management module is installed or the status cannot be
obtained. "power-off" is shown after executing SDN in the process of setting
redundancy.
(*3)
"0" is shown as the number of sensor when no management module is installed.
(*4)
"Not install" is shown if no management module is installed or redundancy setting is on
the process; "Cannot get data" is shown if the data cannot be obtained.
(*5)
"0" is shown if no management module is installed or redundancy setting is on the
process, if the data cannot be obtained, or if no sensor exists.
OID
Syntax
.1.3.6.1.4.1
Integer32
.116.5.39.3
.3.2.1.18
.1.3.6.1.4.1
INTEGER
.116.5.39.3
.3.2.1.19
.1.3.6.1.4.1
Display
.116.5.39.3
String
.3.2.1.20
.1.3.6.1.4.1
Integer32
.116.5.39.3
.3.2.1.21
.1.3.6.1.4.1
INTEGER
.116.5.39.3
.3.2.1.22
.1.3.6.1.4.1
Display
.116.5.39.3
String
.3.2.1.23
.1.3.6.1.4.1
Integer32
.116.5.39.3
.3.2.1.24
1673
Access
Description
RO
Shows the voltage value of the
management module in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1V.
The actual value is one-tenth of
the response value.
Shows the voltage value
RO
validity of the management
module in the slot shown in
#5. One of the following
values is shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the management
module in the slot shown in #5.
(*4)
RO
Shows the voltage value of the
management module in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1V.
The actual value is one-tenth of
the response value.
RO
Shows the voltage value
validity of the management
module in the slot shown in #5.
One of the following values is
shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the management
module in the slot shown in #5.
(*4)
RO
Shows the voltage value of the
management module in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1V.
The actual value is one-tenth of
the response value.