Hitachi Compute Blade 2000 User Manual page 1765

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

(a) ioChassisStatic group (2/2)
Object
No
identifier
13
ioChassisStat
.1.3.6.1.4.1.11
icCurrentPow
6.5.39.11.1.12
er
14
ioChassisStat
.1.3.6.1.4.1.11
icVoltage
6.5.39.11.1.13
15
ioChassisStat
.1.3.6.1.4.1.11
icCurrentType
6.5
.39.11.1.14
16
ioChassisStat
.1.3.6.1.4.1.11
icTempHigher
6.5.39.11.1.15
17
ioChassisStat
.1.3.6.1.4.1.11
icTempLower
6.5.39.11.1.16
18
ioChassisStat
.1.3.6.1.4.1.11
icHeight
6.5.39.11.1.17
19
ioChassisStat
.1.3.6.1.4.1.11
icSize
6.5.39.11.1.18
20
ioChassisStat
.1.3.6.1.4.1.11
icTotalMass
6.5.39.11.1.19
21
ioChassisStat
.1.3.6.1.4.1.11
icUnitNum
6.5.39.11.1.20
22
ioChassisStat
.1.3.6.1.4.1.11
icFMver1
6.5.39.11.1.21
23
ioChassisStat
.1.3.6.1.4.1.11
icFMver2
6.5.39.11.1.22
24
ioChassisStat
.1.3.6.1.4.1.11
icCapacityMa
6.5.39.11.1.23
rlog
OID
Syntax
Integer32
Integer32
INTEGER
Integer32
Integer32
Integer32
Integer32
Integer32
Integer32
DisplayStr
ing
DisplayStr
ing
Integer32
1714
Access
Description
RO
Shows the value of rated
power in the current
configuration of the I/O slot
expansion unit chassis.
Unit: 0.1kW
RO
Shows the value of standard
voltage for the I/O slot
expansion unit chassis.
Unit: 0.1V
RO
Shows the inlet current type
of the I/O slot expansion unit
chassis. One of the following
values is displayed.
1: AC
2.: DC
3: unknown
RO
Shows the high-temperature
warning threshold of inlet air
for the I/O slot expansion
unit chassis. Unit: 0.1°C
RO
Shows the low-temperature
warning threshold of inlet air
for the I/O slot expansion
unit chassis. Unit: 0.1°C
RO
Shows the height of the I/O
slot expansion unit chassis.
Unit: 1U
RO
Shows the size of the I/O
slot expansion unit chassis.
Unit: 1U
RO
Shows the total weight of the
I/O slot expansion unit
chassis in the current
configuration. Unit: 0.1kg
RO
Shows the unit numbert of
the I/O slot expansion unit
chassis.
RO
Shows the firmware version
of the I/O module #0 in the
I/O slot expansion unit
chassis.
RO
Shows the firmware version
of the I/O module #1 in the
I/O slot expansion unit
chassis.
RO
Shows the maximum
number of index for MAR
(Maintenance Action Report)
logs.

Advertisement

Table of Contents
loading

Table of Contents