Hitachi Compute Blade 2000 User Manual page 1723

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

(b) moduleStatusMm group (4/7)
Object
No
identifier
23
mmVoltSensor
4Name
24
mmVoltSensor
4Value
25
mmVoltSensor
4Valid
26
mmVoltSensor
5Name
27
mmVoltSensor
5Value
28
mmVoltSensor
5Valid
29
mmVoltSensor
6Name
(*1)
"unknown" is shown in the process of setting redundancy, or when no management
module is installed or the status cannot be obtained.
(*2)
"unknown" is shown when no management module is installed or the status cannot be
obtained. "power-off" is shown after executing SDN in the process of setting
redundancy.
(*3)
"0" is shown as the number of sensor when no management module is installed.
(*4)
"Not install" is shown if no management module is installed or redundancy setting is on
the process; "Cannot get data" is shown if the data cannot be obtained.
(*5)
"0" is shown if no management module is installed or redundancy setting is on the
process, if the data cannot be obtained, or if no sensor exists.
(*6)
"invalid" is shown if no management module is installed or redundancy setting is on the
process; "unknown" is shown if no data is obtained".
OID
Syntax
.1.3.6.1.4.1.1
Display
16.5.39.3.3.2
String
.1.11
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.2
.1.12
.1.3.6.1.4.1.1
INTEGER
16.5.39.3.3.2
.1.13
.1.3.6.1.4.1.1
Display
16.5.39.3.3.2
String
.1.14
.1.3.6.1.4.1.1
Integer32
16.5.39.3.3.2
.1.15
.1.3.6.1.4.1.1
INTEGER
16.5.39.3.3.2
.1.16
.1.3.6.1.4.1.1
Display
16.5.39.3.3.2
String
.1.17
1672
Access
Description
RO
Shows the voltage sensor
name for the management
module in the slot shown in #5.
(*4)
RO
Shows the voltage value of the
management module in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1 V.
The actual value is one-tenth of
the response value.
RO
Shows the voltage value
validity of the management
module in the slot shown in #5.
One of the following values is
shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the switch and
management module installed
in the slot shown in #5. (*4)
RO
Shows the voltage value of the
management module in the slot
shown in #5. (*5) The value is
shown using the unit of 0.1 V.
The actual value is one-tenth of
the response value.
RO
Shows the voltage value
validity of the management
module in the slot shown in #5.
One of the following values is
shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the management
module in the slot shown in #5.
(*4)